4.4 Quality conformance inspection.
4.4.1 Inspection lot formation. Inspection lots shall comply
with the lot formation provisions of MIL-A-48078 and
MIL-STD-1168,
Inspection lots shall not exceed 500,000 links.
4.4.1.1 Heat treat lot. The heat treat lot shall be limited
to one heat of steel and shall consist of links heat treated in a
batch type furnace at one charge or in a continuous type furnace
during an uninterrupted period extending over not more than one
eight hour shift.
See MIL-A-48078.
4.4.2 Examination.
a. Sampling plans. Unless otherwise specified in the
Classification of Defects, sampling plans and procedures for major
and minor defects shall be in accordance with MIL-STD-105,
Inspection Level II.
b. Inspections to be performed.
See paragraphs 4.4.2.1,
4.4.2.2 and 4.4.2.3.