| ![]() MIL-L-85532(AS)
c.
Height - 44 inches (maximum).
d.
Weight - 6600 pounds (maximum).
3,7.2.2
Fastening devices, All
screws, pins, bolts, and
similar parts shall be installed with means
for preventing loss of
tightness. All such parts, when subject to
removal or adjustment, shall
not be swaged, peened, staked, or otherwise
permanently deformed.
3.7.2.3
Screw threads.
Screw threads shall be in accordance
with FED-STD-H28.
Oil servicing provisions. Oil filler caps shall be
3.7.2.4
painted gloss yellow (color No. 13538) in accordance with FED-STD-595.
The oil to be used and the tank capacity shall be stenciled adjacent to
the filler opening. The stenciling color shall be in accordance with
MIL-STD-808 . The height of the stenciling shall be two inches.
3.7.2.5
Lubrication, All oil holes, grease fittings, and
filler caps shall be accessible. Fittings shall be accessible to a hand
operated grease gun, conforming to MIL-C-3859, with a 10-inch flexible
extension.. A lubrication list in accordance with MIL-STD-838 shall be
provided with the loader. The loader shall operate as specified herein
when lubricated with military lubricants.
3.7.2.6
Hydraulic packing installation. All hydraulic
packings shall be installed in accordance with MIL-G-5514.
3.7.3
Subsystems.
Exhaust system, A spark arrestor conforming to the
3.7.3*1
material and performance requirements of U.S. Department of Agriculture
Forest Service Standard 5100-1, with the exception of an increase in
arrestor efficiency to a 95 percent mean between small and large carbon
particles for each tested flow rate, shall be furnished on the loader,
The exhaust system shall be installed underneath the loader and the
tailpipe located so as to prevent the accumulation of carbon monoxide at
s
the operator location.
3.7.3.2
Electrical system. The loader shall have a nominal
24-volt electric system. Multiple conductor routing shall be protected
by flexible tubing or electrical tape. Grommets shall be provided
whenever wiring passes through bulkheads, partitions, or structural
members, and the wiring shall be fastened to prevent chafing and abrasion,
All wiring shall be color or number coded and be adequately sized, and
all circuits shall have suitable overload protection. Fuses and circuit
breakers shall be grouped in convenient locations and suitably marked
for size and function,
|