MIL-M-29399(MC)
(1)  The launcher shall rotate upwards and the ANGLE OK
light shall go out when the angle of the launcher with respect to
the horizontal exceeds 63 degrees.
(2)  Repeat step f.  No test plugs for any rocket shall
Line charge test plugs shall continue to light.
light.
(3) At the launcher control box, hold the launcher
switch to the LOWER position. The launcher shall rotate down-
wards.  The ANGLE OK light shall come on when the launcher is
at an angle of 63 degrees with the horizontal. It shall remain
on until the angle with horizontal is less than 42 degrees at
which time the light shall go out.
(4)  With the launcher at an angle with the horizontal
of less than 42 degrees (ANGLE OK light not lit), repeat step g.
NO test plugs for any rocket shall light.  Line charge test plugs
shall continue to light.
j.  Alert crew that launcher is to be stowed.  At the launcher control
box, hold the launcher switch at the LOWER position.  The launcher
shall rotate to its maximum downward position and then the launcher
support shall lower to its stowed position within the launcher
housing. During lowering, cams on the support shall engage the
launcher door cam followers, release the door detents and close
the doors.