| MIL-M-38510/117C
TABLE I. Electrical performance characteristics.
Conditions 1/ 2/
Device
Limits
Unit
Test
Symbol
type
-55C ≤ TA ≤ +125C
see figure 9 and 3.5
Min
Max
unless otherwise specified
Input voltage
Load current
01
4.75
5.25
V
Output voltage
VIN = 8 V
IL = -5 mA, -500 mA
VOUT
4.75
5.25
VIN = 30 V
IL = -5 mA, -50 mA
28.5
31.5
VIN = 38 V
IL = -500 mA
4.75
5.25
IL = -5 mA
VIN = 10 V,
TA = 150C
01
-150
150
mV
Line regulation
8 V ≤ VIN ≤ 30 V
IL = -50 mA
VRLINE
-50
50
8 V ≤ VIN ≤ 25 V
IL = -350 mA
01
-100
100
mV
Load regulation
-500 mA ≤ IL ≤ -5 mA
VIN = 10 V
VRLOAD
-150
150
-50 mA ≤ IL ≤ -5 mA
VIN = 30 V
01
-50
50
mV
Thermal regulation
IL = -500 mA
VIN = 15 V,
VRTH
TA = 25C
01
-7.0
-0.5
mA
Standby current drain
VIN = 10 V
IL = -5 mA
ISCD
-8.0
-0.5
VIN = 30 V
IL = -5 mA
01
-1.0
1.0
mA
Standby current drain
8 V ≤ VIN ≤ 30 V
ĆISCD
IL = -5 mA
change versus line
(LINE)
voltage
01
-0.5
0.5
mA
Standby current drain
-500 mA ≤ IL ≤ -5 mA
ĆISCD
VIN = 10 V
change versus load
(LOAD)
current
A
01
-5.0
-0.01
Control pin current
IL = -350 mA
VIN = 10 V,
ICTL
TA = 25C
-8.0
-0.01
IL = -350 mA
VIN = 10 V,
-55C ≤ TA ≤ 125C
See footnotes at end of table.