| MIL-M-38510/117C
NOTE: Case is connected to output.
FIGURE 7. Terminal connections for 03, 04, 05, and 06.
NOTES:
1. VOUT = [((R1 + R2) / R1) x (1.25) + |IADJ| x R2] volts.
R1 = 250 Ω provides a minimum of | 5 mA | load to the regulator at any VOUT.
2.
FIGURE 8. Block diagram for device types 03, 04, 05, and 06.