| MIL-M-38510/117C
TABLE IV. Group C end point electrical parameters. (TA = +25C)
Delta limits 1/
Limits
Units
Device
Characteristic
Symbol
type
Min
Max
50 mV
4.75
5.25
V
01, 02
Output voltage
VOUT 2/
20 %
Standby current drain
-8.0
-0.5
mA
ISCD
10 mV
1.20
1.30
V
03, 04,
Output voltage
VOUT 2/
05
10 mV
1.19
1.29
V
06
Output voltage
VOUT 2/
10 A
A
-100
-15
03, 04,
Adjust pin current
IADJ 3/
05, 06
4 mV
-9
9
mV
03, 04
Line regulation
VRLINE
2 mV
-4
4
mV
05, 06
Line regulation
VRLINE
1/
Delta limits apply to the measured value (see delta limit definition in MIL-PRF-38535).
2/
Delta limits apply to test number 3 for all device types.
3/
Delta limits apply to test number 11 for all device types 03, 04, 05 and test number 12 for device type 06.
5. PACKAGING
5.1 Packaging requirements. For acquisition purposes, the packaging requirements shall be as specified in the contract or
order (see 6.2). When packaging of materiel is to be performed by DoD or in-house contractor personnel, these personnel need
to contact the responsible packaging activity to ascertain packaging requirements. Packaging requirements are maintained by
the Inventory Control Point's packaging activity within the Military Service or Defense Agency, or within the military service's
system command. Packaging data retrieval is available from the managing Military Department's or Defense Agency's
automated packaging files, CD-ROM products, or by contacting the responsible packaging activity.
58
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |