| ![]() MIL-M-38510/118B
TABLE I. Electrical performance characteristics.
Conditions 1/ 2/
Device
Limits
Unit
Test
Symbol
type
-55C ≤ TA ≤ +125C
see figure 9 and 3.5
Min
Max
unless otherwise specified
Input voltage
Load current
01
-5.25
-4.75
V
Output voltage
VIN = -8 V
IL = 5 mA, 500 mA
VOUT
-5.25
-4.75
VIN = -30 V
IL = 5 mA, 50 mA
-31.5
-28.5
VIN = -38 V
IL = 500 mA
-5.25
-4.75
IL = 5 mA
VIN = -10 V,
TA = 150C
01
-150
150
mV
Line regulation
-30 V ≤ VIN ≤ -8 V
IL = 50 mA
VRLINE
-50
50
-25 V ≤ VIN ≤ -8 V
IL = 350 mA
01
-100
100
mV
Load regulation
5 mA ≤ IL ≤ 500 mA
VIN = -10 V
VRLOAD
-150
150
5 mA ≤ IL ≤ 50 mA
VIN = -30 V
01
-50
50
mV
Thermal regulation
IL = 500 mA
VIN = -15 V,
VRTH
TA = 25C
01
0.1
3.0
mA
Standby current drain
VIN = -10 V
IL = 5 mA
ISCD
0.1
4.0
VIN = -30 V
IL = 5 mA
01
-1.0
1.0
mA
Standby current drain
-30 V ≤ VIN ≤ -8 V
ĆISCD
IL = 5 mA
change versus line
(LINE)
voltage
01
-0.5
0.5
mA
Standby current drain
5 mA ≤ IL ≤ 500 mA
ĆISCD
VIN = -10 V
change versus load
(LOAD)
current
A
01
0.001
2.00
Control pin current
IL = 350 mA
VIN = -10 V,
ICTL
TA = 25C
0.001
3.00
IL = 350 mA
VIN = -10 V,
-55C ≤ TA ≤ 125C
See footnotes at end of table.
5
|