| MIL-M-38510/118B
TABLE IV. Group C end point electrical parameters. (TA = +25C)
Delta limits 1/
Limits
Units
Device
Characteristic
Symbol
type
Min
Max
50 mV
01, 02
Output voltage
-5.25
-4.75
V
VOUT
20 %
Standby current drain
0.5
4.0
mA
ISCD
10 mV
03, 04
Output voltage
-1.275
-1.225
V
VOUT
10 A
A
Adjust pin current
25
100
IADJ
4 mV
Line regulation
-9
9
mV
VRLINE
1/
Delta limits apply to the measured value (see delta limit definition in MIL-PRF-38535).
6. NOTES
(This section contains information of a general or explanatory nature that may be helpful, but it is not mandatory.)
6.1 Intended use. Microcircuits conforming to this specification are intended for original equipment design applications and
logistic support of existing equipment.
6.2 Acquisition requirements. Acquisition documents should specify the following:
a.
Title, number, and date of the specification.
b.
Pin and compliance identifier, if applicable (see 1.2).
c.
Requirements for delivery of one copy of the quality conformance inspection data pertinent to the device inspection
lot to be supplied with each shipment by the device manufacturer, if applicable.
d.
Requirements for certificate of compliance, if applicable.
e.
Requirements for notification of change of product or process to contracting activity in addition to notification to the
qualifying activity, if applicable.
f.
Requirements for failure analysis (including required test condition of method 5003 of MIL-STD-883), corrective
action, and reporting of results, if applicable.
g.
Requirements for product assurance options.
h.
Requirements for special carriers, lead lengths, or lead forming, if applicable. These requirements should not affect
the part number. Unless otherwise specified, these requirements will not apply to direct purchase by or direct
shipment to the Government.
i.
Requirements for "JAN" marking.
j.
Packaging requirements (see 5.1).