| ![]() TABLE III. Group A inspection for device type 01 - Continued. 1/
MIL-
Case J, K,
1
2
3
4
5
6
7
8
9
10
11
12
Subgroup
Symbol
STD-
L, Z
Test limits
883
Meas
Test No.
S3
S2
S1
S0
Cn
M
GND
B0
A0
F0
F1
F2
method
terminal
Min
Max
Unit
9
tPLH8
3003
222
GND
IN
GND
4.5 V
4.5 V
GND
GND
GND
GND
7
58
ns
A0 to A = B
TC = 25C
(Fig 4)
223
"
4.5 V
"
"
"
"
"
"
"
"
"
"
A1 to A = B
"
224
"
"
"
"
"
"
"
"
"
"
"
"
A2 to A = B
"
225
"
"
"
"
"
"
"
"
"
"
"
"
A3 to A = B
"
226
IN
"
"
"
"
"
"
"
"
"
"
"
B0 to A = B
"
227
GND
"
"
"
"
"
"
"
"
"
"
"
B1 to A = B
"
228
"
"
"
"
"
"
"
"
"
"
"
"
B2 to A = B
"
229
"
"
"
"
"
"
"
"
"
"
"
"
B3 to A = B
tPHL9
"
230
GND
4.5 V
4.5 V
GND
GND
4.5 V
IN
GND
"
Cn to Cn+4
7
23
ns
tPLH9
"
231
GND
4.5 V
4.5 V
GND
GND
4.5 V
IN
GND
"
Cn to Cn+4
7
22
ns
tPHL10
"
232
4.5 V
4.5 V
GND
4.5 V
4.5 V
GND
IN
GND
"
Cn to Cn+4
7
23
ns
tPLH10
"
233
4.5 V
4.5 V
GND
4.5 V
4.5 V
GND
IN
GND
"
Cn to Cn+4
7
22
ns
tPHL11
"
234
GND
IN
4.5 V
GND
GND
4.5 V
GND
GND
"
7
34
ns
A0 to Cn + 4
"
235
4.5 V
GND
"
"
"
"
"
"
"
"
"
"
A1 to Cn + 4
"
236
"
"
"
"
"
"
"
"
"
"
"
"
A2 to Cn + 4
"
237
"
"
"
"
"
"
"
"
"
"
"
"
A3 to Cn + 4
"
238
IN
"
"
"
"
"
"
"
"
"
"
"
B0 to Cn + 4
"
239
4.5 V
"
"
"
"
"
"
"
"
"
"
"
B1 to Cn + 4
"
240
"
"
"
"
"
"
"
"
"
"
"
"
B2 to Cn + 4
"
241
"
"
"
"
"
"
"
"
"
"
"
"
B3 to Cn + 4
tPLH11
"
242
GND
IN
4.5 V
GND
GND
4.5 V
GND
GND
"
7
40
ns
A0 to Cn + 4
"
243
4.5 V
GND
"
"
"
"
"
"
"
"
"
"
A1 to Cn + 4
"
244
"
"
"
"
"
"
"
"
"
"
"
"
A2 to Cn + 4
"
245
"
"
"
"
"
"
"
"
"
"
"
"
A3 to Cn + 4
"
246
IN
"
"
"
"
"
"
"
"
"
"
"
B0 to Cn + 4
"
247
4.5 V
"
"
"
"
"
"
"
"
"
"
"
B1 to Cn + 4
"
248
"
"
"
"
"
"
"
"
"
"
"
"
B2 to Cn + 4
"
249
"
"
"
"
"
"
"
"
"
"
"
"
B3 to Cn + 4
See notes at end of table for device type 01.
|