| TABLE III. Group A inspection for device type 01 - Continued. 1/
MIL-
Case J,
13
14
15
16
17
18
19
20
21
22
23
24
Subgroup
Symbol
STD-
K, L, Z
Test limits
883
Meas
Test No.
A=B
Cn+4
VCC
F3
G
B3
A3
B2
A2
B1
A1
P
method
terminal
Min
Max
Unit
9
tPHL12
3003
250
OUT
GND
GND
GND
GND
GND
GND
5.0 V
7
40
ns
A0 to Cn + 4
TC = 25C
(Fig 4)
251
"
"
"
GND
GND
4.5 V
IN
"
"
"
"
A1 to Cn + 4
"
252
"
"
"
4.5 V
IN
GND
GND
"
"
"
"
A2 to Cn + 4
"
253
"
4.5 V
IN
GND
GND
"
"
"
"
"
"
A3 to Cn + 4
"
254
"
GND
GND
"
"
"
"
"
"
"
"
B0 to Cn + 4
"
255
"
"
"
"
"
IN
"
"
"
"
"
B1 to Cn + 4
"
256
"
"
"
IN
"
GND
"
"
"
"
"
B2 to Cn + 4
"
257
"
IN
"
GND
"
GND
"
"
"
"
"
B3 to Cn + 4
tPLH12
"
258
"
GND
GND
GND
GND
GND
GND
"
7
40
ns
A0 to Cn + 4
"
259
"
"
"
GND
GND
4.5 V
IN
"
"
"
"
A1 to Cn + 4
"
260
"
"
"
4.5 V
IN
GND
GND
"
"
"
"
A2 to Cn + 4
"
261
"
4.5 V
IN
GND
GND
"
"
"
"
"
"
A3 to Cn + 4
"
262
"
GND
GND
"
"
"
"
"
"
"
"
B0 to Cn + 4
"
263
"
"
"
"
"
IN
"
"
"
"
"
B1 to Cn + 4
"
264
"
"
"
IN
"
GND
"
"
"
"
"
B2 to Cn + 4
"
265
"
IN
"
GND
"
GND
"
"
"
"
"
B3 to Cn + 4
tPHL13
"
266
"
GND
GND
GND
GND
GND
GND
"
7
36
ns
A 0 to F 0
"
267
"
"
"
"
GND
"
IN
"
"
"
"
A 1 to F 1
"
268
"
"
"
"
IN
"
GND
"
"
"
"
A 2 to F 2
"
269
OUT
"
"
IN
"
GND
"
"
"
"
"
"
A 3 to F 3
"
270
"
"
GND
"
"
"
"
"
"
"
"
B 0 to F 0
"
271
"
"
"
"
"
IN
"
"
"
"
"
B 1 to F 1
"
272
"
"
"
IN
"
GND
"
"
"
"
"
B 2 to F 2
"
273
OUT
"
IN
"
GND
"
GND
"
"
"
"
"
B 3 to F 3
tPLH13
"
274
"
GND
GND
GND
GND
GND
GND
"
7
50
ns
A 0 to F 0
"
275
"
"
"
"
GND
"
IN
"
"
"
"
A 1 to F 1
"
276
"
"
"
"
IN
"
GND
"
"
"
"
A 2 to F 2
"
277
OUT
"
"
IN
"
GND
"
"
"
"
"
"
A 3 to F 3
"
278
"
"
GND
"
"
"
"
"
"
"
"
B 0 to F 0
"
279
"
"
"
"
"
IN
"
"
"
"
"
B 1 to F 1
"
280
"
"
"
IN
"
GND
"
"
"
"
"
B 2 to F 2
"
281
OUT
"
IN
"
GND
"
GND
"
"
"
"
"
B 3 to F 3
See notes at end of table for device type 01.
|