| ![]() MIL-M-38510/125B
TABLE IV. Group C end point electrical parameters.
(TA = 25C, VCC = 15 V for all device types)
Table III
Test
Limits
Delta limits
Units
test no.
Min
Max
Min
Max
-3
+3
-0.5
+0.5
mV
4
VIO
-1
25
-2.5
2.5
nA
9
IIB
6.0 NOTES
This section contains information of a general or explanatory nature that may be helpful, but it is not mandatory.
6.1 Intended use. Microcircuits conforming to this specification are intended for original equipment design applications and
logistic support of existing equipment.
6.2 Acquisition requirements. Acquisition documents should specify the following:
a.
Title, number, and date of the specification.
b.
PIN and compliance identifier, if applicable (see 1.2).
c.
Requirements for delivery of one copy of the conformance inspection data pertinent to the device inspection lot to be
supplied with each shipment by the device manufacturer, if applicable.
d.
Requirements for certificate of compliance, if applicable.
e.
Requirements for notification of change of product or process to contracting activity in addition to notification to the
qualifying activity, if applicable.
f.
Requirements for failure analysis (including required test condition of method 5003 of MIL-STD-883), corrective
action, and reporting of results, if applicable.
g.
Requirements for product assurance options.
h.
Requirements for special carriers, lead lengths, or lead forming, if applicable. These requirements should not affect
the part number. Unless otherwise specified, these requirements will not apply to direct purchase by or direct
shipment to the Government.
i.
Requirements for "JAN" marking.
j.
Packaging requirements (see 5.1).