| TABLE III. Group A inspection for device type 01 Continued.
Limits
Subgroup
Symbol
Equations and notes
Test
Energized relays
Unit
Min
Max
no.
No.
Value
Unit
1
1
K1, K2, K9, K10, K11
9
E1
V
-5
5
mV
VIO
VIO = (E1 2.5 V) / 101
A
Tc =
2
K1, K9, K10, K11
9
E2
"
0.01
10
+IIB
+IIB = (E1 E2) / 101000
A
+25C
3
K2, K9, K10, K11
9
E3
"
0.01
10
-IIB = (E3 E1) / 101000
-IIB
A
A
4
9
I1
65
170
ICOS1
ICOS1 = I1
A
5
9
I2
"
-170
-65
ICOS2
ICOS2 = I2
A
6
-1
1
IIO
IIO = ( +IIB ) ( -IIB )
CMR
7
K1, K2, K9, K10, K11
9
E4
V
CMR = 20 log [ (3.4 1.8) 101 / (E5 E4 1.6) ]
70
dB
9
E5
"
8
16
E6
"
4.8
5.2
V
VREF
VREF = E6
9
"
E7
"
-20
20
mV
VRLINE
VRLINE = E8 E7
"
E8
"
10
"
E9
"
-50
50
mV
VRLOAD
VRLOAD = E9 E6
11
"
I3
mA
-190
mA
IOS
IOS = I3
12
7
E10
V
0.7
1.1
V
VSAT
VSAT(OSC) = E10
(OSC)
A
A
13
12
14
10
ICEX(A)
ICEX(A) = I4
A
A
14
13
15
10
ICEX(B)
ICEX(B) = I5
15
12
E11
V
2.0
V
VSAT(A)
VSAT(A) = E11
16
13
E12
"
2.0
V
VSAT(B)
VSAT(B) = E12
17
11
E13
"
17
V
VEO(A)
VEO(A) = E13
18
14
E14
"
17
V
VEO(B)
VEO(B) = E14
19
15
I6
mA
10
mA
IIN
IIN = I6
2
20
K1, K2, K9, K10, K11
9
E15
V
-5
5
mV
VIO
VIO = (E15 2.5 V) / 101
A
Tc =
21
K1, K9, K10, K11
9
E16
"
0.01
10
+IIB
+IIB = (E15 E16) / 101000
+125C
A
22
K2, K9, K10, K11
9
E17
"
0.01
10
-IIB = (E17 E15) / 101000
-IIB
A
23
-1
1
IIO
IIO = ( +IIB ) ( -IIB )
CMR
24
K1, K2, K9, K10, K11
9
E18
V
CMR = 20 log [ (3.4 1.8) 101 / (E19 E18 1.6) ]
70
dB
9
E19
"
25
16
E20
"
4.8
5.2
V
VREF
VREF = E20
26
"
E21
"
-20
20
mV
VRLINE
VRLINE = E22 E21
"
E22
"
27
"
E23
"
-50
50
mV
VRLOAD
VRLOAD = E23 E20
28
"
I7
mA
-120
mA
IOS
IOS = I7
A
A
29
12
I8
10
ICEX(A)
ICEX(A) = I8
A
A
30
13
I9
10
ICEX(B)
ICEX(B) = I9
31
12
E24
V
2.0
V
VSAT(A)
VSAT(A) = E24
32
13
E25
"
2.0
V
VSAT(B)
VSAT(B) = E25
33
15
I10
mA
10
mA
IIN
IIN = I10
3
34 to
Tc = -55C
47
See footnotes at end of table.
|