| MIL-M-38510/126C
TABLE III. Group A inspection - Continued.
NOTES:
12/ VN = 2.5 V. Equation for CMR is as follows:
CMR = 20 Log [ 5.2 V (201) / | ( EX EY 5.2) | ]
Test number 19: EX = E17, EY = E16
Test number 50: EX = E40, EY = E39
Test number 81: EX = E63, EY = E62
13/ VN = 0.5 V to 3.5 V. Equation for AVS is as follows:
AVS = 20 Log ( ĆVN (201) / | ĆEX | )
Test number 101: ĆEX = E73
Test number 118: ĆEX = E84
Test number 135: ĆEX = E95
14/ VN = 2.5 V. Equation for PSRR is as follows:
PSRR = 20 Log [ ĆVIN (201) / | ( EX EY ) | ]
Test number 102: ( EX EY ) = ( E75 E74 )
Test number 119: ( EX EY ) = ( E86 E85 )
Test number 136: ( EX EY ) = ( E97 E96 )
15/ Increase voltage on +C.S. until V shutdown ≤ 0.4 V. Record V +C.S.
16/ See figure 4.