| MIL-M-38510/13G
NOTES:
1.
The pulse generator has the following characteristics: Vgen = 3 V, t0 = t1 < 15 ns,
tp = .5 s, PRR ≤ 1 MHz, ZOUT ≈ 50Ω.
2.
All diodes are 1N3064 or equivalent.
CL includes probe and jig capacitance.
3.
4.
Voltage values are with respect to ground terminal.
5.
FMAX pulse generator has the following characteristics: Vgen = 3.0 V 0.2 V, t0 = t1 < 10 ns,
tp = 50 ns, PRR = 10 MHz.
FIGURE 6. Switching time test circuit and waveforms for device type 02.
35
|