Page Title: Table 3. Group A inspection for device type 01-cont.
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home

   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 




img
TABLE III. Group A inspection for device type 01 Continued.
Terminal conditions 13/
Case A,B,D
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Test limits
MIL-
Case C
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Subgroup
Symbol
STD-883
Meas.
method
QD
QC
GND
QB
QA
NC
In A
Test No.
In BC
NC
NC
NC
R0(1)
R0(2)
VCC
Min
Max
Unit
terminal
9/
Fig 5
66
5.0 V
GND
GND
12/
9
12/
GND
12/
OUT 11/
IN
QA
10
MHz
FMAX
"
67
10/
"
"
"
OUT 11/
11/
"
11/
10/ 11/
"
QD
20
100
ns
TC = 25C
tPLH1
"
68
10/
"
"
"
OUT 11/
11/
"
11/
10/ 11/
"
QD
20
100
ns
tPHL1
9/
Fig 5
69
"
"
"
12/
10
12/
"
12/
OUT 11/
IN
QA
10
MHz
FMAX
"
70
10/
"
"
"
OUT 11/
11/
"
11/
10/ 11/
"
QD
20
115
ns
TC = 125C
tPLH1
"
71
10/
"
"
"
OUT 11/
11/
"
11/
10/ 11/
"
QD
20
115
ns
tPHL1
11
Same tests, terminal conditions and limits as for subgroup 10, except TC = -55C.
1/
Momentarily apply 2.4 V, then ground prior to taking measurements to set the device in desired state. Maintain ground for measurement.
2/
Apply 4.5 V pulse then ground prior to taking measurements to set the device in the desired state. Maintain ground for measurement.
A 2.0 V, B 0.8 V. Input voltages shown are the maximum for VIL and the minimum for VIH.
3/
4/
Only a summary of attributes data is required.
5/
Output voltages shall be either:
(a) H = 2.4 volts minimum and L = 0.4 volt maximum when using a high speed checker double comparator, or
(b) H 1.5 volts and L 1.5 volts when using a high speed checker single comparator.
6/ Input must be applied 3 times after R0 pulses.
7/ Input must be applied 2 times after R0 pulses.
8/ Input must be applied once after R0 pulses.
9/
FMAX, minimum limit specified is the frequency of the input pulse. The output frequency shall be one-half of the input frequency.
10/
Connect terminals together during test.
11/
See test figure 5 for terminal load.
12/
Omit specified loads for this test.
Terminal conditions (pins not designated may be H 2.0 V, or L 0.8 V, or open).
13/
14/
The limits shown shall be as follows:
Min/Max limits (ma) for circuit:
Test
A
B
C
D
E
IIL1
-0.4/-1.3
-0.4/-1.3
-0.3/-1.3
-0.7/-1.6
-0.7/-1.6
IIL2
-1.4/-3.2
-0.7/-3.2
-0.7/-3.2
-0.7/-3.2
-0.7/-3.2
IIL3
-1.4/-4.8
-0.7/-4.8
-0.7/-4.8
-1.4/-6.4
-1.4/-6.4