TABLE III. Group A inspection for device type 02 - Continued
Terminal conditions 13/
Case A, B, D
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Test limits
MIL-
Case C
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Subgroup
Symbol
STD-883
Meas.
method
NC
NC
NC
QC
QB
GND
QD
QA
Test No.
In B
In A
R0(1)
R0 (2)
VCC
terminal
Min
Max
Unit
NC
7
Func-
3014
72
B
A
A
4.5 V
L
L
GND
L
L
B 5/
tional
"
73
"
B
B
"
"
"
"
"
"
A
TC = 25C
tests 4/
"
74
"
"
"
"
"
"
"
"
H
B
See 3/
"
"
75
"
"
"
"
"
"
"
"
H
A
"
"
76
"
"
"
"
"
"
"
"
L
B
8
Repeat subgroup 7 at TC = 125C and TC = -55C.
Fig 6
77
GND
GND
5.0 V
12/
9
12/
GND
OUT 11/
IN
QA
10
MHz
FMAX9/
"
78
10/
"
"
"
11/
11/
"
OUT 11/
10/ 11/
N
QD
20
135
ns
TC = 25C
tPLH2
"
79
10/
"
"
"
11/
11/
"
OUT 11/
10/ 11/
IN
QD
20
135
ns
tPHL2
Fig 6
80
"
"
"
12/
10
12/
"
OUT 11/
IN
QA
10
MHz
FMAX9/
"
81
10/
"
"
"
11/
11/
"
OUT 11/
10/ 11/
IN
QD
20
135
ns
TC = 125C
tPLH2
"
82
10/
"
"
"
11/
11/
"
OUT 11/
10/ 11/
IN
QD
20
135
ns
tPHL2
11
Same tests, terminal conditions and limits as for subgroup 10, except TC = -55C.
1/ Momentarily apply 2.4 V, then ground prior to taking measurements to set the device in desired state. Maintain ground for measurement.
2/ Apply 4.5 V pulse, then ground prior to taking measurements to set the device in desired state. Maintain ground for measurement.
3/ Output voltages shall be either:
(a) H = 2.4 volts minimum and L = 0.4 volt maximum when using a high speed checker double comparator, or
(b) H 1.5 volts and L 1.5 volts when using a high speed checker single comparator.
4/ Only a summary of attributes data is required.
5/ A 2.0 V, B 0.8 V. Input voltages shown are the maximum for VIL and the minimum for VIH.
6/ Input pulse must be applied 1 time after R0 pulses.
7/ Input pulse must be applied 2 times after R0 pulses.
8/ Input pulse must be applied 4 times after R0 pulses.
9/ FMAX, minimum limit specified is the frequency of the input pulse. The output frequency shall be one-half of the input frequency.
10/ Connect terminals together during test.
11/ See test figure 6 for terminal load.
12/ Omit specified loads for this test.
13/ Terminal conditions (pins not designated may be H 2.0 V, or L 0.8 V, or open).
14/ The limits shown are as follows:
Min/Max limits (mA) for circuit:
Test
A
B
C
D
E
IIL1
-0.4/-1.3
-0.4/-1.3
-0.4/-1.3
-0.7/-1.6
-0.7/-1.6
IIL2
-0.7/-3.2
-0.7/-3.2
-0.7/-3.2
-0.7/-3.2
-0.7/-3.2
IIL3
-0.7/-3.2
-0.7/-3.2
-0.7/-3.2
-0.7/-3.2
-0.7/-3.2