| TABLE III. Group A inspection for device type 07.
Terminal conditions 12/
Case C, D
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Test limits
MIL-
Input
Reset
Reset
Reset
Reset
Output
Output
Output
Output
Input
Subgroup
Symbol
STD-883
Meas.
Test No.
NC
VCC
GND
BD
R0(1)
Min
Max
Unit
R9 (1)
R0 (2)
R9 (2)
QC
QB
QD
QA
NC
A
method
terminal
1
VOL
3007
1
2.0 V
2.0 V
2.0 V
4.5 V
GND
GND
16 mA
GND
GND
QC
0.4
V
TC = 25C
"
2
2.0 V
"
"
"
GND
GND
16 mA
"
GND
QB
"
"
"
3
2.0 V
"
"
"
4.5 V
0.8 V
"
16 mA
GND
QD
"
"
"
4
GND
"
"
"
0.8 V
4.5 V
"
16 mA
2.0 V
QA
"
"
"
5
2.0 V
4.5 V
0.8 V
"
2.0 V
2.0 V
16 mA
"
GND
QC
"
"
"
6
2.0 V
0.8 V
4.5 V
"
"
"
16 mA
"
GND
QB
"
"
VOH
3006
7
2.0 V
4.5 V
0.8 V
"
"
"
"
-0.4 mA
GND
QD
2.4
V
"
8
GND
0.8 V
4.5 V
"
"
"
"
-0.4 mA
2.0 V
QA
"
"
"
9
2.0 V
"
0.8 V
"
"
"
"
-0.4 mA
GND
QD
"
"
"
10
GND
"
0.8 V
"
"
"
"
-0.4 mA
2.0 V
QA
"
"
"
11
1/ 4/
1/
1/
"
0.8 V
0.8 V
-0.4 mA
"
GND
QC
"
"
"
12
1/ 3/
1/
1/
"
0.8 V
0.8 V
-0.4 mA
"
GND
QB
"
"
IIL1
3009
13
0.4 V
4.5 V
5.5 V
"
R0(1)
13/
13/
mA
R0(2)
"
"
"
"
"
14
4.5 V
0.4 V
"
"
"
"
"
15
"
0.4 V
4.5 V
"
Rg(1)
"
"
"
"
16
"
4.5 V
0.4 V
"
R0(2)
"
"
"
IIL2
"
17
GND
GND
"
2/
2/
"
0.4 V
Input A
"
"
"
IIL3
"
18
0.4 V
GND
GND
"
2/
2/
"
Input BD
"
"
"
VIC
19
-12 mA
4.5 V
"
R0(1)
-1.5
V
"
20
-12 mA
"
"
R0(2)
"
"
"
21
"
-12 mA
"
Rg(1)
"
"
"
22
"
-12 mA
"
R0(2)
"
"
"
23
GND
GND
"
GND
GND
"
-12 mA
Input A
"
"
"
24
-12 mA
GND
GND
"
GND
GND
"
Input BD
"
"
See footnotes at end of device type 07.
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |