| TABLE III. Group A inspection for device type 01 Continued.
Limits
MIL-
Pin number and signal designation
Subgroup
Symbol
STD-
Test
Measured
Min
Max
Unit
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
883
no.
terminal
method
GND COM OUT7
IN2
IN3
IN4
IN5
IN6
IN7
OUT6
OUT5
OUT4
OUT3
OUT2
OUT1
IN1
1
43
0V
0V
350 mA
2.0
V
VF
OUT1
44
"
"
350 mA
"
"
OUT2
TA =
+25C
"
"
45
"
"
350 mA
OUT3
46
"
"
350 mA
"
"
OUT4
47
"
"
350 mA
"
"
OUT5
48
"
"
350 mA
"
"
OUT6
49
"
"
350 mA
"
"
OUT7
1000
3003
50
"
350 mA IB1-OUT1
hFE
IB1
"
51
"
350 mA
IB2-OUT2
IB2
"
52
"
350 mA
IB3-OUT3
IB3
"
53
"
350 mA
IB4-OUT4
IB4
"
350 mA
"
54
IB5-OUT5
IB5
"
55
"
350 mA
IB6-OUT6
IB6
"
350 mA
"
56
IB7-OUT7
IB7
A
2
57
0V
50 V
10.0
ICEX
OUT1
58
"
50 V
"
"
TA =
OUT2
+125C
"
"
59
"
50 V
OUT3
"
"
60
"
50 V
OUT4
61
"
50 V
"
"
OUT5
"
"
62
"
50 V
OUT6
63
"
50 V
"
"
OUT7
500 A
3007
64
"
350 mA
1.8
V
VCE(sat)
OUT1
500 A
"
350 mA
65
"
"
OUT2
500 A
"
350 mA
66
"
"
OUT3
500 A
"
350 mA
67
"
"
OUT4
500 A
"
"
"
350 mA
68
OUT5
500 A
"
"
"
350 mA
69
OUT6
500 A
"
"
"
350 mA
70
OUT7
350 A
1.5
V
3007
71
"
200 mA
VCE(sat)
OUT1
350 A
"
200 mA
72
"
"
OUT2
350 A
"
200 mA
73
"
"
OUT3
350 A
"
200 mA
74
"
"
OUT4
350 A
"
"
"
200 mA
75
OUT5
350 A
"
200 mA
76
"
"
OUT6
350 A
"
200 mA
77
"
"
OUT7
250 A
3007
78
"
100 mA
1.3
V
VCE(sat)
OUT1
250 A
"
100 mA
79
"
"
OUT2
250 A
"
100 mA
80
"
"
OUT3
250 A
"
"
"
100 mA
81
OUT4
250 A
"
"
"
100 mA
82
OUT5
250 A
"
100 mA
83
"
"
OUT6
250 A
"
"
"
100 mA
84
OUT7
|