| TABLE III. Group A inspection for device type 02.
Limits
MIL-
Pin number and signal designation
Subgroup
Symbol
STD-
Test
Measured
Min
Max
Unit
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
883
no.
terminal
method
GND COM OUT7
IN2
IN3
IN4
IN5
IN6
IN7
OUT6
OUT5
OUT4
OUT3
OUT2
OUT1
IN1
A
1
1
0V
50 V
10.0
ICEX
OUT1
2
"
50 V
"
"
TA =
OUT2
+25C
"
"
3
"
50 V
OUT3
4
"
50 V
"
"
OUT4
5
"
50 V
"
"
OUT5
6
"
50 V
"
"
OUT6
7
"
50 V
"
"
OUT7
500 A
3007
8
"
350 mA
1.6
V
VCE(sat)
OUT1
500 A
"
350 mA
9
"
"
OUT2
500 A
"
350 mA
10
"
"
OUT3
500 A
"
350 mA
11
"
"
OUT4
500 A
"
"
"
350 mA
12
OUT5
500 A
"
350 mA
13
"
"
OUT6
500 A
"
"
"
350 mA
14
OUT7
350 A
3007
15
"
200 mA
1.3
V
VCE(sat)
OUT1
350 A
"
200 mA
16
"
"
OUT2
350 A
"
"
200 mA
17
"
OUT3
350 A
"
"
"
200 mA
18
OUT4
350 A
"
200 mA
19
"
"
OUT5
350 A
"
"
"
200 mA
20
OUT6
350 A
"
200 mA
21
"
"
OUT7
250 A
3007
22
"
100 mA
1.1
V
VCE(sat)
OUT1
250 A
"
100 mA
23
"
"
OUT2
250 A
"
100 mA
24
"
"
OUT3
250 A
"
100 mA
25
"
"
OUT4
250 A
"
"
"
100 mA
26
OUT5
250 A
"
"
"
100 mA
27
OUT6
250 A
"
"
"
100 mA
28
OUT7
A
29
17 V
"
575
1300
IIN(on)
IN1
30
17 V
"
"
"
"
IN2
31
17 V
"
"
"
"
IN3
32
17 V
"
"
"
"
IN4
"
"
"
33
17 V
"
IN5
34
17 V
"
"
"
"
IN6
35
17 V
"
"
"
"
IN7
25 A
A
36
"
50 V
500
IIN(off)
OUT1
25 A
37
"
50V
"
"
OUT2
25 A
38
"
50 V
"
"
OUT3
25 A
"
"
39
"
50 V
OUT4
25 A
"
"
40
"
50 V
OUT5
25 A
41
"
50 V
"
"
OUT6
25 A
"
"
"
50 V
42
OUT7
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |