| TABLE III. Group A inspection for device type 02 Continued.
Limits
MIL-
Pin number and signal designation
Subgroup
Symbol
STD-
Test
Measured
Min
Max
Unit
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
883
no.
terminal
method
GND COM OUT7
IN2
IN3
IN4
IN5
IN6
IN7
OUT6
OUT5
OUT4
OUT3
OUT2
OUT1
IN1
350 A
2
3007
85
0V
200 mA
1.5
V
VCE(sat)
OUT1
350 A
"
200 mA
86
"
"
OUT2
TA =
+125C
350 A
"
200 mA
"
"
87
OUT3
350 A
"
200 mA
88
"
"
OUT4
350 A
"
200 mA
89
"
"
OUT5
350 A
"
200 mA
90
"
"
OUT6
350 A
"
200 mA
91
"
"
OUT7
250 A
3007
92
"
100 mA
1.3
V
VCE(sat)
OUT1
250 A
"
100 mA
93
"
"
OUT2
250 A
"
100 mA
94
"
"
OUT3
250 A
"
100 mA
95
"
"
OUT4
250 A
"
"
"
100 mA
96
OUT5
250 A
"
100 mA
97
"
"
OUT6
250 A
"
"
"
100 mA
98
OUT7
A
99
17 V
"
575
1300
IIN(on)
IN1
100
17 V
"
"
"
"
IN2
"
101
17 V
"
"
"
IN3
"
"
"
102
17 V
"
IN4
103
17 V
"
"
"
"
IN5
"
"
"
104
17 V
"
IN6
105
17 V
"
"
"
"
IN7
25 A
A
106
"
50 V
500
IIN(off)
OUT1
25 A
107
"
50V
"
"
OUT2
25 A
108
"
50 V
"
"
OUT3
25 A
109
"
50 V
"
"
OUT4
25 A
"
"
110
"
50 V
OUT5
25 A
"
"
111
"
50 V
OUT6
25 A
"
"
"
50 V
112
OUT7
2.0
V
113
13 V
0V
300 mA
VIN(on)
OUT1
114
13 V
"
300 mA
"
"
OUT2
115
13 V
"
300 mA
"
"
OUT3
116
13 V
"
300 mA
"
"
OUT4
"
"
117
13 V
"
300 mA
OUT5
118
13 V
"
300 mA
"
"
OUT6
119
13 V
"
300 mA
"
"
OUT7
A
0V
COM
10.0
120
"
50 V
IR
121
"
"
0V
COM
"
"
122
"
"
0V
COM
"
"
123
"
"
0V
COM
"
"
124
"
"
0V
COM
"
"
125
"
"
0V
COM
"
"
126
"
"
0V
COM
"
"
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |