| TABLE III. Group A inspection for device type 03 Continued.
Limits
MIL-
Pin number and signal designation
Subgroup
Symbol
STD-
Test
Measured
Min
Max
Unit
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
883
no.
terminal
method
GND COM OUT7
IN2
IN3
IN4
IN5
IN6
IN7
OUT6
OUT5
OUT4
OUT3
OUT2
OUT1
IN1
2
127
2.0 V
0V
200 mA
2.0
V
VIN(on)
OUT1
128
2.0 V
"
200 mA
"
"
OUT2
TA =
+125C
"
"
129
2.0 V
"
200 mA
OUT3
130
2.0 V
"
200 mA
"
"
OUT4
131
2.0 V
"
200 mA
"
"
OUT5
132
2.0 V
"
200 mA
"
"
OUT6
133
2.0 V
"
200 mA
"
"
OUT7
134
2.2 V
0V
250 mA
2.0
V
VIN(on)
OUT1
135
2.2 V
"
250 mA
"
"
OUT2
136
2.2 V
"
250 mA
"
"
OUT3
"
"
137
2.2 V
"
250 mA
OUT4
138
2.2 V
"
250 mA
"
"
OUT5
"
"
139
2.2 V
"
250 mA
OUT6
"
"
140
2.2 V
"
250 mA
OUT7
V
141
2.4 V
0V
300 mA
2.0
VIN(on)
OUT1
142
2.4 V
"
300 mA
"
"
OUT2
"
"
143
2.4 V
"
300 mA
OUT3
144
2.4 V
"
300 mA
"
"
OUT4
"
"
145
2.4 V
"
300 mA
OUT5
146
2.4 V
"
300 mA
"
"
OUT6
"
"
147
2.4 V
"
300 mA
OUT7
A
0V
COM
10.0
148
"
50 V
IR
149
"
"
0V
COM
"
"
150
"
"
0V
COM
"
"
151
"
"
0V
COM
"
"
152
"
"
0V
COM
"
"
153
"
"
0V
COM
"
"
154
"
"
0V
COM
"
"
155
0V
0V
350 mA
2.0
V
VF
OUT1
156
"
"
350 mA
"
"
OUT2
"
"
157
"
"
350 mA
OUT3
"
"
158
"
"
350 mA
OUT4
159
"
"
350 mA
"
"
OUT5
160
"
"
350 mA
"
"
OUT6
161
"
"
350 mA
"
"
OUT7
1000
3003
162
"
350 mA IB1-OUT1
hFE
IB1
"
350 mA
"
163
IB2-OUT2
IB2
"
164
"
350 mA
IB3-OUT3
IB3
"
165
"
350 mA
IB4-OUT4
IB4
"
166
"
350 mA
IB5-OUT5
IB5
"
167
"
350 mA
IB6-OUT6
IB6
"
350 mA
"
168
IB7-OUT7
IB7
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |