| TABLE III. Group A inspection for device type 04 Continued.
Limits
MIL-
Pin number and signal designation
Subgroup
Symbol
STD-
Test
Measured
Min
Max
Unit
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
883
no.
terminal
method
GND COM OUT7
IN2
IN3
IN4
IN5
IN6
IN7
OUT6
OUT5
OUT4
OUT3
OUT2
OUT1
IN1
1
85
0V
0V
350 mA
2.0
V
VF
OUT1
86
"
"
350 mA
"
"
OUT2
TA =
+25C
"
"
87
"
"
350 mA
OUT3
88
"
"
350 mA
"
"
OUT4
89
"
"
350 mA
"
"
OUT5
90
"
"
350 mA
"
"
OUT6
91
"
"
350 mA
"
"
OUT7
1000
3003
92
"
350 mA IB1-OUT1
hFE
IB1
"
93
"
350 mA
IB2-OUT2
IB2
"
94
"
350 mA
IB3-OUT3
IB3
"
95
"
350 mA
IB4-OUT4
IB4
"
350 mA
"
96
IB5-OUT5
IB5
"
97
"
350 mA
IB6-OUT6
IB6
"
98
"
350 mA
IB7-OUT7
IB7
A
2
99
0V
50 V
10.0
ICEX
OUT1
100
"
50 V
"
"
TA =
OUT2
+125C
"
101
"
50 V
"
OUT3
"
"
102
"
50 V
OUT4
103
"
50 V
"
"
OUT5
"
"
104
"
50 V
OUT6
105
"
50 V
"
"
OUT7
500 A
1.8
V
3007
106
"
350 mA
VCE(sat)
OUT1
500 A
"
350 mA
107
"
"
OUT2
500 A
"
350 mA
108
"
"
OUT3
500 A
"
350 mA
109
"
"
OUT4
500 A
"
"
"
350 mA
110
OUT5
500 A
"
350 mA
111
"
"
OUT6
500 A
"
"
"
350 mA
112
OUT7
350 A
1.5
V
3007
113
"
200 mA
VCE(sat)
OUT1
350 A
"
200 mA
114
"
"
OUT2
350 A
"
"
"
200 mA
115
OUT3
350 A
"
"
"
200 mA
116
OUT4
350 A
"
200 mA
117
"
"
OUT5
350 A
"
"
"
200 mA
118
OUT6
350 A
"
200 mA
119
"
"
OUT7
250 A
3007
120
"
100 mA
1.3
V
VCE(sat)
OUT1
250 A
"
100 mA
121
"
"
OUT2
250 A
"
"
"
100 mA
122
OUT3
250 A
"
100 mA
123
"
"
OUT4
250 A
"
100 mA
124
"
"
OUT5
250 A
"
"
"
100 mA
125
OUT6
250 A
"
"
"
100 mA
126
OUT7
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |