| TABLE III. Group A inspection for device type 04 - Continued.
Limits
MIL-
Pin number and signal designation
Subgroup
Symbol
STD-
Test
Measured
Min
Max
Unit
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
883
no.
terminal
method
GND COM OUT7
IN2
IN3
IN4
IN5
IN6
IN7
OUT6
OUT5
OUT4
OUT3
OUT2
OUT1
IN1
9
750
ns
3003
295
0V
OUT
tPLH
IN1
IN1-OUT1
Fig. 4
"
"
296
"
OUT
TA =
IN2
IN2-OUT2
+25C
"
"
"
OUT
297
IN3-OUT3
IN3
"
"
298
"
OUT
IN4
IN4-OUT4
"
"
299
"
OUT
IN5
IN5-OUT5
"
"
300
"
OUT
IN6
IN6-OUT6
"
"
301
"
OUT
IN7
IN7-OUT7
300
ns
3003
302
"
OUT
tPHL
IN1
IN1-OUT1
Fig. 4
"
"
303
"
OUT
IN2
IN2-OUT2
"
"
304
"
OUT
IN3
IN3-OUT3
"
OUT
"
"
305
IN4-OUT4
IN4
"
"
306
"
OUT
IN5
IN5-OUT5
"
"
307
"
OUT
IN6
IN6-OUT6
"
"
OUT
"
308
IN7-OUT7
IN7
NOTE: Pins not designated are open.
|