| ![]() TABLE III. Group A inspection for device type 07 - Continued.
Limits
MIL-
Pin number and signal designation
Subgroup Symbol
STD- Test
Measured
Min
Max
Unit
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
883
no.
terminal
method
GND COM
IN2
IN3
IN4
IN5
IN6
IN7
IN8
OUT8
OUT7
OUT6
OUT5
OUT4
OUT3
OUT2
OUT1
IN1
9
750
ns
3003
241
0V
OUT
tPLH
IN1
IN1-OUT1
Fig. 4
"
"
242
"
OUT
TA =
IN2
IN2-OUT2
+25C
"
"
"
OUT
243
IN3-OUT3
IN3
"
"
244
"
OUT
IN4
IN4-OUT4
"
"
245
"
OUT
IN5
IN5-OUT5
"
"
246
"
OUT
IN6
IN6-OUT6
"
"
247
"
OUT
IN7
IN7-OUT7
"
"
248
"
OUT
IN8
IN8-OUT8
300
ns
3003
249
"
OUT
tPHL
IN1
IN1-OUT1
Fig. 4
"
"
250
"
OUT
IN2
IN2-OUT2
"
OUT
"
"
251
IN3-OUT3
IN3
"
"
252
"
OUT
IN4
IN4-OUT4
"
"
253
"
OUT
IN5
IN5-OUT5
"
OUT
"
"
254
IN6-OUT6
IN6
"
"
255
"
OUT
IN7
IN7-OUT7
"
"
OUT
"
256
IN8-OUT8
IN8
NOTE: Pins not designated are open.
|