| ![]() TABLE III. Group A inspection for device type 09 - Continued.
Limits
MIL-
Pin number and signal designation
Subgroup Symbol
STD- Test
Measured
Min
Max
Unit
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
883
no.
terminal
method
GND COM
IN2
IN3
IN4
IN5
IN6
IN7
IN8
OUT8
OUT7
OUT6
OUT5
OUT4
OUT3
OUT2
OUT1
IN1
500 A
2
3007
121
0V
350 mA
1.8
V
VCE(sat)
OUT1
500 A
"
350 mA
122
"
"
OUT2
TA =
+125C
500 A
"
350 mA
"
"
123
OUT3
500 A
"
350 mA
124
"
"
OUT4
500 A
"
350 mA
125
"
"
OUT5
500 A
"
350 mA
126
"
"
OUT6
500 A
"
350 mA
127
"
"
OUT7
500 A
"
350 mA
128
"
"
OUT8
350 A
3007
129
"
200 mA
1.5
V
VCE(sat)
OUT1
350 A
"
200 mA
130
"
"
OUT2
350 A
"
"
"
200 mA
131
OUT3
350 A
"
200 mA
132
"
"
OUT4
350 A
"
200 mA
133
"
"
OUT5
350 A
"
"
"
200 mA
134
OUT6
350 A
"
"
200 mA
135
"
OUT7
350 A
"
"
"
200 mA
136
OUT8
250 A
1.3
V
3007
137
"
100 mA
VCE(sat)
OUT1
250 A
"
100 mA
138
"
"
OUT2
250 A
"
"
"
100 mA
139
OUT3
250 A
"
100 mA
140
"
"
OUT4
250 A
"
100 mA
141
"
"
OUT5
250 A
"
100 mA
142
"
"
OUT6
250 A
"
"
"
100 mA
143
OUT7
250 A
"
100 mA
144
"
"
OUT8
A
145
5.0 V
"
250
500
IIN(on)
IN1
146
5.0 V
"
"
"
"
IN2
"
"
"
147
5.0 V
"
IN3
148
5.0 V
"
"
"
"
IN4
149
5.0 V
"
"
"
"
IN5
150
5.0 V
"
"
"
"
IN6
"
"
"
151
5.0 V
"
IN7
"
"
"
152
5.0 V
"
IN8
A
153
12 V
"
750
1450
IIN(on)
IN1
154
12 V
"
"
"
"
IN2
"
"
"
155
12 V
"
IN3
156
12 V
"
"
"
"
IN4
157
12 V
"
"
"
"
IN5
158
12 V
"
"
"
"
IN6
159
12 V
"
"
"
"
IN7
160
12 V
"
"
"
"
IN8
|