| TABLE III. Group A inspection for device type 03 - Continued.
Terminal conditions (pins not designated may be H ≥ 2.0 V, or L ≤ 0.8 V, or open).
MIL- Cases E, F
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Test limits
Subgroup Symbol STD-883
Meas.
method Test No.
1G
B
1Y
GND
2Y
A
2G
Min
Max
Unit
1C3
1C2
1C1
1C0
2C1
2C2
2C3
2C0
VCC terminal
10
3003
109
GND
GND
5.0 V
GND
OUT
GND
IN
5.0 V A to 1Y
6
44
ns
tPHL2
"
(Fig 5)
110
GND
IN
5.0 V
GND
OUT
"
GND
"
B to 1Y
"
"
"
TC = 125C
"
"
"
111
GND
"
OUT
GND
5.0 V
IN
GND
"
A to 2Y
"
"
"
"
"
"
112
IN
"
OUT
GND
5.0 V
GND
GND
"
B to 2Y
"
"
"
"
"
113
GND
GND
5.0 V
GND
OUT
"
IN
"
A to 1Y
"
42
"
tPLH2
"
"
"
114
GND
IN
5.0 V
GND
OUT
"
GND
"
B to 1Y
"
"
"
"
"
"
115
GND
"
OUT
GND
5.0 V
IN
GND
"
A to 2Y
"
"
"
"
"
"
116
IN
"
OUT
GND
5.0 V
GND
GND
"
B to 2Y
"
"
"
"
"
117
IN
GND
5.0 V
OUT
"
GND
"
1G to 1Y
"
32
"
tPHL3
"
118
GND
"
OUT
5.0 V
GND
IN
"
2G to 2Y
"
32
"
"
tPHL3
"
"
119
IN
GND
5.0 V
OUT
"
GND
"
1G to 1Y
"
42
"
tPLH3
"
120
GND
"
OUT
5.0 V
GND
IN
"
2G to 2Y
"
42
"
"
tPLH3
11
Same tests, terminal conditions and limits as subgroup 10, except TC = -55C.
1/ A = 3.0 V minimum, B = 0.0 V or GND.
2/ H > 1.5 V; L < 1.5 V.
Only attributes data is required for subgroups 7 and 8.
|