| TABLE III. Group A inspection for device type 05 Continued.
Terminal conditions (pins not designated may be H ≥ 2.0 V, or L ≤ 0.8 V, or open).
MIL- Cases E, F
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Test limits
Subgroup Symbol STD-883
Meas.
method Test No.
A
1Y
2Y
GND
4Y
3Y
G
Min
Max
Unit
1B0
1B1
2B0
2B1
4B1
4B0
3B1
3B0
VCC
terminal
10
3003
103
5.0 V
5.0 V
OUT
GND
IN
5.0 V
G to 1Y
3
33
ns
tPLH2
"
(Fig 6)
104
"
5.0 V
OUT
"
"
"
G to 2Y
"
"
"
TC = 125C
"
"
"
105
"
"
OUT
5.0 V
"
"
G to 3Y
"
"
"
"
"
"
106
"
"
OUT
5.0 V
"
"
G to 4Y
"
"
"
"
25
"
"
"
107
GND
IN
OUT
"
GND
"
1B0 to 1Y
tPHL3
"
"
"
"
"
"
108
5.0 V
IN
OUT
"
"
"
1B1 to 1Y
"
"
"
"
"
"
109
GND
IN
OUT
"
"
"
2B0 to 2Y
"
"
"
"
"
"
110
5.0 V
IN
OUT
"
"
"
2B1 to 2Y
"
"
"
"
"
"
111
GND
"
OUT
IN
"
"
3B0 to 3Y
"
"
"
"
"
"
112
5.0 V
"
OUT
IN
"
"
3B1 to 3Y
"
"
"
"
"
"
113
GND
"
OUT
IN
"
"
4B0 to 4Y
"
"
"
"
"
"
114
5.0 V
"
OUT
IN
"
"
4B1 to 4Y
"
35
"
"
"
115
GND
IN
OUT
"
"
"
1B0 to 1Y
tPLH3
"
"
"
"
"
"
116
5.0 V
IN
OUT
"
"
"
1B1 to 1Y
"
"
"
"
"
"
117
GND
IN
OUT
"
"
"
2B0 to 2Y
"
"
"
"
"
"
118
5.0 V
IN
OUT
"
"
"
2B1 to 2Y
"
"
"
"
"
"
119
GND
"
OUT
IN
"
"
3B0 to 3Y
"
"
"
"
"
"
120
5.0 V
"
OUT
IN
"
"
3B1 to 3Y
"
"
"
"
"
"
121
GND
"
OUT
IN
"
"
4B0 to 4Y
"
"
"
"
"
"
122
5.0 V
"
OUT
IN
"
"
4B1 to 4Y
11
Same tests, terminal conditions and limits as subgroup 10, except TC = -55C.
1/ A = 3.0 V minimum, B = 0.0 V or GND.
2/ H > 1.5 V; L < 1.5 V.
Only attributes data is required for subgroups 7 and 8.
|