| TABLE III. Group A inspection for device type 02.
Terminal conditions (pins not designated may be H > 2.0 V or L < 0.8 V or open).
Test limits
Case A,B,C,D
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Subgroup
Symbol
MIL-
Meas.
CLOCK
CLOCK
STD-883
terminal
Test No.
1D
2D
VCC
3D
4D
NC
4Q
3Q
NC
GND
2Q
1Q
Min
Max
Unit
3-4
1-2
method
1
3006
1
2.0 V
4.5 V
GND
2.0 V
-0.4 mA
1Q
2.4
V
VOH
"
"
2
2.0 V
"
"
2.0 V
-0.4 mA
2Q
"
"
TC =25C
"
"
3
2.0 V
"
2.0 V
-0.4 mA
"
3Q
"
"
"
"
4
2.0 V
"
2.0 V
-0.4 mA
"
4Q
"
"
3007
5
0.8 V
"
"
2.0 V
16 mA
1Q
0.4
"
VOL
"
"
6
0.8 V
"
"
2.0 V
16 mA
2Q
"
"
"
"
7
2.0 V
"
0.8 V
16 mA
"
3Q
"
"
"
"
8
2.0 V
"
0.8 V
16 mA
"
4Q
"
"
mA
3009
9
0.4 V
5.5 V
"
4.5 V
1D
-1.4
-3.2
IIL1
"
"
10
0.4 V
"
"
4.5 V
2D
"
"
"
"
"
11
4.5 V
"
0.4 V
"
3D
"
"
"
"
"
12
4.5 V
"
0.4 V
"
4D
"
"
"
"
13
0.8 V
0.8 V
"
"
0.4 V
CLK 1-2
-2.8
-6.4
"
IIL2
"
14
0.4 V
"
0.8 V
0.8 V
"
CLK 3-4
-2.8
-6.4
"
IIL2
A
3010
15
2.4 V
"
"
GND
1D
80
IIH1
"
"
16
2.4 V
"
"
GND
2D
"
"
"
"
17
GND
"
2.4 V
"
3D
"
"
"
"
18
GND
"
2.4 V
"
4D
"
"
"
19
5.5 V
"
"
GND
1D
200
"
IIH2
"
"
20
5.5 V
"
"
GND
2D
"
"
"
"
21
GND
"
5.5 V
"
3D
"
"
"
"
22
GND
"
5.5 V
"
4D
"
"
"
23
GND
GND
"
"
2.4 V
CLK 1-2
160
"
IIH3
"
24
2.4 V
"
GND
GND
"
CLK 3-4
160
"
IIH3
"
25
GND
GND
"
"
5.5 V
CLK 1-2
400
"
IIH4
"
26
5.5 V
"
GND
GND
"
CLK 3-4
400
"
IIH4
3011
27
4.5 V
"
"
4.5 V
GND
1Q
-20
-57
mA
IOS
"
"
28
4.5 V
"
"
4.5 V
GND
2Q
"
"
"
"
"
29
4.5 V
"
4.5 V
GND
"
3Q
"
"
"
"
"
30
4.5 V
"
4.5 V
GND
"
4Q
"
"
"
3005
31
GND
GND
GND
"
GND
GND
"
GND
VCC
46
"
ICC
32
-12 mA
4.5 V
"
1D
-1.5
V
VIC
"
33
-12 mA
"
"
2D
"
"
"
34
"
-12 mA
"
3D
"
"
"
35
"
-12 mA
"
4D
"
"
"
36
"
"
-12 mA
CLK 1-2
"
"
"
37
-12 mA
"
"
CLK 3-4
"
"
2
Same tests, terminal conditions and limits as for subgroup 1, except TC = 125C and VI C tests are omitted.
3
Same tests, terminal conditions and limits as for subgroup 1, except TC = -55C and VI C tests are omitted.
See footnotes at end of device type 02.
|