| TABLE III. Group A inspection for device type 04.
Terminal conditions (pins not designated may be H > 2.0 V or L < 0.8 V or open).
MIL-
Cases E, F
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Test limits
Subgroup
Symbol
STD-883
Meas.
S0
S2
S3
S1
method
terminal
Min
Max
Unit
E
MR
VCC
Q3
Test No.
D0
D1
D2
D3
GND
Q2
Q1
Q0
3003
62
IN
GND
IN
GND
5.0 V
OUT
5.0 V
9
29
ns
9
tPHL1
E -Q0
TC = 25C
"
Fig 7-C
63
"
IN
"
"
OUT
GND
"
"
"
"
E -Q1
"
"
"
64
"
GND
IN
"
"
OUT
"
"
"
"
E -Q2
"
"
"
65
"
IN
"
"
OUT
GND
"
"
"
"
E -Q3
3003
66
"
GND
IN
"
"
OUT
"
D0-Q0
"
21
ns
"
tPLH2
"
"
Fig 7-B
67
"
IN
"
"
OUT
GND
"
D1-Q1
"
"
"
"
"
"
68
"
GND
IN
"
"
OUT
"
D2-Q2
"
"
"
"
"
"
69
"
IN
"
"
OUT
GND
"
D3-Q3
"
"
"
"
3003
70
"
GND
IN
"
"
OUT
"
D0-Q0
"
"
"
tPLH2
"
"
Fig 7-C
71
"
IN
"
"
OUT
GND
"
D1-Q1
"
"
"
"
"
"
72
"
GND
IN
"
"
OUT
"
D2-Q2
"
"
"
"
"
"
73
"
IN
"
"
OUT
GND
"
D3-Q3
"
"
"
"
3003
74
GND
GND
IN
"
"
OUT
"
D0-Q0
"
"
"
tPLH2
"
"
Fig 7-D
75
"
IN
"
"
OUT
GND
"
D1-Q1
"
"
"
"
"
"
76
"
GND
IN
"
"
OUT
"
D2-Q2
"
"
"
"
"
"
77
"
IN
"
"
OUT
GND
"
D3-Q3
"
"
"
"
"
3003
78
"
GND
IN
"
"
OUT
"
D0-Q0
3
30
tPHL2
"
"
Fig 7-E
79
"
IN
"
"
OUT
GND
"
D1-Q1
"
"
"
"
"
"
80
"
GND
IN
"
"
OUT
"
D2-Q2
"
"
"
"
"
"
81
"
IN
"
"
OUT
GND
"
D3-Q3
"
"
"
"
3003
82
IN
GND
IN
"
"
OUT
"
D0-Q0
"
"
"
tPHL2
"
"
Fig 7-A
83
"
IN
"
"
OUT
GND
"
D1-Q1
"
"
"
"
"
"
84
"
GND
IN
"
"
OUT
"
D2-Q2
"
"
"
"
"
"
85
"
IN
"
"
OUT
GND
"
D3-Q3
"
"
"
"
3003
86
"
GND
5.0 V
"
IN
OUT
"
9
23
"
tPHL3
MR -Q0
"
"
Fig 7-F
87
"
5.0 V
"
"
OUT
GND
"
"
"
"
MR -Q1
"
"
"
88
"
GND
5.0 V
"
"
OUT
"
"
"
"
MR -Q2
"
"
"
89
"
5.0 V
"
"
OUT
GND
"
"
"
"
MR -Q3
"
3003
90
GND
IN
IN
"
5.0 V
OUT
"
"
29
"
tPLH4
S 0-Q0
"
"
Fig 7-E
91
"
IN
"
"
OUT
IN
"
"
"
"
S 1-Q1
"
"
"
92
"
IN
IN
"
"
OUT
"
"
"
"
S 2-Q2
"
"
"
93
"
IN
"
"
OUT
IN
"
"
"
"
S 3-Q3
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |