| TABLE III. Group A inspection for device type 02.
Terminal conditions (pins not designated are open)
Meas.
Subgroup
Symbol
MIL-
Cases
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Test limits
STD-883
terminal
Min
Max
Unit
A,B,C,D
method
Test No.
1A
1B
1Y
2A
2B
2Y
GND
3Y
3A
3B
4Y
4A
4B
VCC
1
VOL
3007
1
0.8 V
5.5 V
16 mA
5.5 V
5.5 V
GND
5.5 V
5.5 V
5.5 V
5.5 V
4.5 V
1Y
0.4
V
"
"
2
5.5 V
0.8 V
16 mA
5.5 V
"
"
"
"
"
"
"
1Y
"
"
TC = 25C
"
"
3
"
5.5 V
0.8 V
"
16 mA
"
"
"
"
"
"
2Y
"
"
"
"
"
4
"
"
5.5 V
0.8 V
16 mA
"
"
"
"
"
"
2Y
"
"
"
"
"
5
"
"
"
5.5 V
"
16 mA
0.8 V
"
"
"
"
3Y
"
"
"
"
"
6
"
"
"
"
"
16 mA
5.5 V
0.8 V
"
"
"
3Y
"
"
"
"
"
7
"
"
"
"
"
"
5.5 V
16 mA
0.8 V
"
"
4Y
"
"
"
"
"
8
"
"
"
"
"
"
"
16 mA
5.5 V
0.8 V
"
4Y
"
"
"
A
ICEX
9
2.0 V
2.0 V
5.5 V
"
"
"
"
"
"
5.5 V
"
1Y
250
"
"
10
5.5 V
5.5 V
2.0 V
2.0 V
5.5 V
"
"
"
"
"
"
2Y
"
"
"
"
11
"
"
5.5 V
5.5 V
"
5.5 V
2.0 V
2.0 V
"
"
"
3Y
"
"
"
"
12
"
"
5.5 V
5.5 V
"
5.5 V
5.5 V
5.5 V
2.0 V
2.0 V
"
4Y
"
"
"
"
IIH1
3010
13
2.4 V
GND
GND
GND
"
GND
GND
GND
GND
5.5 V
1A
40
"
"
"
"
14
GND
2.4 V
GND
"
"
"
"
"
"
"
1B
"
"
"
"
"
15
"
GND
2.4 V
"
"
"
"
"
"
"
2A
"
"
"
"
"
16
"
"
GND
2.4 V
"
"
"
"
"
"
2B
"
"
"
"
"
17
"
"
"
GND
"
2.4 V
"
"
"
"
3A
"
"
"
"
"
18
"
"
"
"
"
GND
2.4 V
"
"
"
3B
"
"
"
"
"
19
"
"
"
"
"
"
GND
2.4 V
"
"
4A
"
"
"
"
"
20
"
"
"
"
"
"
"
GND
2.4 V
"
4B
"
"
"
IIH2
"
21
5.5 V
"
"
"
"
"
"
"
"
"
1A
100
"
"
"
"
22
GND
5.5 V
"
"
"
"
"
"
"
"
1B
"
"
"
"
"
23
"
GND
5.5 V
"
"
"
"
"
"
"
2A
"
"
"
"
"
24
"
"
GND
5.5 V
"
"
"
"
"
"
2B
"
"
"
"
"
25
"
"
"
GND
"
5.5 V
"
"
"
"
3A
"
"
"
"
"
26
"
"
"
"
"
GND
5.5 V
"
"
"
3B
"
"
"
"
"
27
"
"
"
"
"
"
GND
5.5 V
"
"
4A
"
"
"
"
"
28
"
"
"
"
"
"
GND
GND
5.5 V
"
4B
"
"
"
IIL
3009
29
0.4 V
5.5 V
5.5 V
5.5 V
"
5.5 V
5.5 V
5.5 V
5.5 V
"
1A
-0.7
-1.6
mA
"
"
"
30
5.5 V
0.4 V
5.5 V
"
"
"
"
"
"
"
1B
"
"
"
"
"
"
31
"
5.5 V
0.4 V
"
"
"
"
"
"
"
2A
"
"
"
"
"
"
32
"
"
5.5 V
0.4 V
"
"
"
"
"
"
2B
"
"
"
"
"
"
33
"
"
"
5.5 V
"
0.4 V
"
"
"
"
3A
"
"
"
"
"
"
34
"
"
"
"
"
5.5 V
0.4 V
"
"
"
3B
"
"
"
"
"
"
35
"
"
"
"
"
"
5.5 V
0.4 V
"
"
4A
"
"
"
"
"
"
36
"
"
"
"
"
"
"
5.5 V
0.4 V
"
4B
"
"
"
"
"
33
"
ICCL
3005
37
GND
GND
GND
GND
"
GND
GND
GND
GND
"
VCC
"
ICCH
3005
38
5.5 V
5.5 V
5.5 V
5.5 V
"
5.5 V
5.5 V
5.5 V
5.5 V
"
21
"
"
VCC
"
VIC
39
-12 mA
"
4.5 V
1A
-1.5
V
"
"
40
-12 mA
"
"
1B
"
"
"
"
41
-12 mA
"
"
2A
"
"
"
"
42
-12 mA
"
"
2B
"
"
"
"
43
"
-12 mA
"
3A
"
"
"
"
44
"
-12 mA
"
3B
"
"
"
"
45
"
-12 mA
"
4A
"
"
"
"
46
"
-12 mA
"
4B
"
"
2
Same tests, terminal conditions and limits as subgroup 1, except TC = 125C and VIC tests are omitted.
3
Same tests, terminal conditions and limits as subgroup 1, except TC = -55C and VIC tests are omitted.
|