| TABLE III. Group A inspection for device type 02.
Terminal conditions (pins not designated may be high ≥ 2.0V or low ≤ 0.8 V or open).
Subgroup
Case E & F
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Test limits
Symbol
MIL-
Meas.
STD-883
terminal
Min
Max
Unit
Test No.
1D
2D
2Q
GND
Clock
3Q
3D
4D
4Q
VCC
Clear
1Q
1Q
2Q
3Q
4Q
method
10
fMAX
Fig 4
91
5.0 V
OUT
IN
GND
IN
5.0 V
1Q
25
MHz
TC = 125C
5/
"
92
"
IN
OUT
"
"
"
2Q
"
"
"
"
93
"
"
"
OUT
IN
"
3Q
"
"
"
"
94
"
"
"
IN
OUT
"
4Q
"
"
tPLH1
3003
95
IN
OUT
5.0 V
"
"
"
5
36
ns
Clear-1 Q
"
Fig 7
96
"
5.0 V
OUT
"
"
"
"
"
"
Clear-2 Q
"
"
97
"
"
"
OUT
5.0 V
"
"
"
"
Clear-3 Q
"
"
98
"
"
"
5.0 V
OUT
"
"
"
"
Clear-4 Q
tPHL1
"
99
"
OUT
5.0 V
"
"
"
Clear-1Q
"
50
"
"
"
100
"
5.0 V
OUT
"
"
"
Clear-2Q
"
"
"
"
"
101
"
"
"
OUT
5.0 V
"
Clear-3Q
"
"
"
"
"
102
"
"
"
5.0 V
OUT
"
Clear-4Q
"
"
"
tPLH2,
3003
103 & 104
5.0 V
OUT
IN
"
"
"
Clock-1Q
"
43
"
tPHL2
Fig 4 & 5
105 & 106
"
IN
OUT
"
"
"
Clock-2Q
"
"
"
"
"
107 & 108
"
"
"
OUT
IN
"
Clock-3Q
"
"
"
"
"
109 & 110
"
"
"
IN
OUT
"
Clock-4Q
"
"
"
"
"
"
tPLH3,
"
111 & 112
"
OUT
IN
"
"
"
Clock-1 Q
tPHL3
"
113 & 114
"
IN
OUT
"
"
"
"
"
"
Clock-2 Q
"
"
115 & 116
"
"
"
OUT
IN
"
"
"
"
Clock-3 Q
"
"
117 & 118
"
"
"
IN
OUT
"
"
"
"
Clock-4 Q
Same tests, terminal conditions and limits as subgroup 10, except TC = -55C.
11
1/ B = Momentary GND, then VCC.
2/ The tests in subgroups 7 and 8 shall be performed in the sequence specified.
3/ Output voltages shall be either:
(a) H = 2.4 V minimum and L = 0.4 V maximum when using a high speed checker double comparator, or
(b) H > 1.5 V and L < 1.5 V when using a high speed checker single comparator.
4/ Only a summary of attributes data is required.
5/ fMAX minimum limit specified is the frequency of the input pulse. The output frequency shall be one half of the input frequency.
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |