| MIL-M-38510/203E
TABLE IVD. Programming characteristics for circuit G.
Limits 1/
Unit
Parameter
Symbol
Conditions
Min
Rec
Max
Required VCC for
VCCP
10.0
10.5
11.0
V
programming
VCC = 11 V
ICC during programming
ICCP
750
mA
Required output voltage
VOP
10.0
10.5
11.0
V
for programming
Output current while
IOP
VOUT = 11 V
20
mA
programming
V/μs
IRR
Rate of voltage change of
1.0
10.0
VCC or output
μs
Programming pulse width
PWE
9
10
11
(Enabled)
Required VCC for
VCCV
3.8
4.0
4.2
V
verification
MDC
25
25
%
Maximum duty cycle for
VCC at VCCP
Address set-up time
t1
100
ns
VCCP set-up time
t2
2/
5
ns
VCCP hold time
t5
100
ns
VOP set-up time
t3
100
ns
VOP hold time
t4
100
ns
1/ TC = +25C
2/ VCCP set-up time may be greater than 0 if VCCP rises at the same rate or faster than VOP.
5. PACKAGING
5.1 Packaging requirements. For acquisition purposes, the packaging requirements shall be as specified in the
contract or order (see 6.2). When packaging of materiel is to be performed by DoD or in-house contractor personnel,
these personnel need to contact the responsible packaging activity to ascertain packaging requirements. Packaging
requirements are maintained by the Inventory Control Point's packaging activity within the Military Service or Defense
Agency, or within the military service's system command. Packaging data retrieval is available from the managing
Military Department's or Defense Agency's automated packaging files, CD-ROM products, or by contacting the
responsible packaging activity.
30
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |