| TABLE III. Group A inspection for devices type 02 and 04 Continued.
Terminal conditions (outputs not designated are open or resistive coupled to GND or voltage;
inputs not designated are ≥ 2.0 V, low ≤ 0.8 V).
Cases
MIL-
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Test limits
Measured
E,F
STD-
Subgroup Symbol
Unit
terminal
883
Test
O2
GND
Min
Max
O3
O4
O5
O6
O7
O8
A0
A1
A2
A3
A4
VCC
O1
CE
method
no.
μA
-40
43
1
0.5V
GND
5.5V
5.5V
O1
IOLZ
"
44
O2
0.5V
"
"
"
TC =
"
O3
45
0.5V
"
"
"
25C
O4
"
46
0.5V
"
"
"
O5
"
47
0.5V
"
"
"
O6
"
48
0.5V
"
"
"
O7
"
49
0.5V
"
"
"
O8
"
50
"
0.5V
"
"
3005
51
"
GND
GND
GND
GND
GND
GND
"
VCC
130
mA
ICC
-10
3011
1/ 11/ 1/ 11/ 1/ 11/ 1/ 11/ 1/ 11/
-100
0.5V
52
"
"
GND
O1
"
IOS
"
12/ 13/ 12/ 13/ 12/ 13/ 12/ 13/ 12/ 13/
"
O2
"
"
53
"
"
GND
"
"
"
"
"
"
"
O3
"
"
"
54
"
"
GND
"
O4
"
"
"
"
"
"
"
"
"
55
"
"
GND
"
O5
"
"
"
"
"
"
"
"
"
56
"
"
GND
"
O6
"
"
"
"
"
"
"
"
"
57
"
"
GND
"
O7
"
"
"
"
"
"
"
"
"
58
"
"
GND
"
O8
"
"
"
"
"
"
"
"
"
59
"
"
"
GND
Same tests, terminal conditions, and limits as for subgroup 1, except TC = 125C and VIC tests are omitted.
2
Same tests, terminal conditions, and limits as for subgroup 1, except TC = -55C and VIC tests are omitted.
3
7
6/
60
6/
6/
6/
6/
6/
6/
6/
GND
6/
6/
6/
6/
6/
6/
6/
6/
Outputs
6/
Func-
tional
TC =
tests
25C
Same tests, terminal conditions, and limits as for subgroup 7, except TC = 125C and TC = -55C.
8
tPHL1 GALPAT
61
7/
9
7/
7/
7/
7/
7/
7/
GND
7/
8/
8/
8/
8/
8/
GND
8/
Outputs
9/
ns
Fig. 4
TC =
tPLH1 GALPAT
62
"
"
"
"
"
"
"
"
"
8/
8/
8/
8/
8/
GND
8/
"
9/
"
25C
Fig. 4
tPHL2 Sequen-
10/
10/
10/
10/
10/
10/
10/
"
9/
"
63
"
"
"
"
"
"
"
"
"
tial
Fig. 4
tPLH2 Sequen-
10/
10/
10/
10/
10/
10/
10/
"
9/
"
64
"
"
"
"
"
"
"
"
"
tial
Fig. 4
Same tests, terminal conditions, and limits as for subgroup 9, except TC = 125C.
10
Same tests, terminal conditions, and limits as for subgroup 9, except TC = -55C.
11
See footnotes at end of table.
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |