| TABLE III. Group A inspection for device type 03. Continued. 1/
Cases
Subgroup Symbol
MIL-
Test limits
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Measured
Unit
A,B,C,D
STD-883
terminal
Min
Max
method Test no.
Q2
Q1
Clock 1 Clear 1
K1
VCC
Clock 2 Clear 2
J2
Q2
K2
GND
Q1
J1
B
4.5 V
L 3/
H or L
B
GND
All
H 3/
B
L 3/
B
H 3/
A
A
B
7
B
43
TC=+25C
A
"
as shown 3/
"
"
outputs
"
"
"
"
A
"
"
"
"
"
44
B
"
"
"
"
"
"
"
"
B
"
"
"
"
"
45
2/ 4/
B
"
A
"
"
"
A
"
"
B
"
"
"
"
"
46
A
"
"
"
"
"
"
"
"
A
"
"
"
"
"
47
B
"
"
"
"
"
"
"
"
B
"
"
"
"
"
48
B
"
"
"
"
A
"
"
"
B
"
"
"
"
A
49
A
"
"
"
"
"
"
"
"
A
"
"
"
"
"
50
B
"
"
"
"
"
"
"
"
B
L
H
H
L
"
51
A
"
"
"
"
"
"
"
"
A
L
H
H
L
"
52
B
"
"
"
"
"
"
"
"
B
H
L
L
H
"
53
A
"
"
"
"
"
"
"
"
A
H
L
L
H
"
54
B
"
"
"
"
"
"
"
"
B
L
H
H
L
"
55
B
"
B
"
"
"
B
B
B
B
"
"
"
"
"
56
A
"
"
"
"
"
"
"
"
A
"
"
"
"
"
57
B
"
"
"
"
"
"
"
"
B
"
"
"
"
"
58
"
"
"
"
"
B
"
"
"
"
H
L
L
H
B
59
"
"
"
"
"
A
"
"
"
"
"
"
"
"
A
60
A
"
"
"
"
"
"
"
"
A
"
"
"
"
"
61
B
"
"
"
"
"
"
"
"
B
"
"
"
"
"
62
B
"
"
"
"
"
"
A
A
"
"
"
"
"
"
63
A
"
"
"
"
"
"
"
"
A
"
"
"
"
"
64
B
"
"
"
"
"
"
"
"
B
L
H
H
L
"
65
B
"
A
"
"
"
A
B
B
B
"
"
"
"
"
66
A
"
"
"
"
"
"
"
"
A
"
"
"
"
"
67
B
"
"
"
"
"
"
"
"
B
H
L
L
H
"
68
A
"
"
"
"
B
"
A
A
A
"
"
"
"
B
69
"
"
"
"
"
A
"
A
A
"
"
"
"
"
A
70
"
"
"
"
"
"
"
B
B
"
"
"
"
"
"
71
"
"
B
"
"
"
B
"
"
"
"
"
"
"
"
72
B
"
B
"
"
"
B
"
"
B
L
H
H
L
"
73
"
A
"
"
"
A
A
A
A
"
"
"
"
"
74
A
"
B
"
"
"
B
A
A
"
"
"
"
"
"
75
"
"
"
"
"
"
"
B
B
"
"
"
"
"
"
76
"
"
"
"
"
"
"
B
B
B
H
L
L
H
"
77
B
"
"
"
"
"
"
A
A
A
H
L
L
H
"
78
A
"
"
"
"
"
"
"
"
B
L
H
H
L
"
79
B
"
"
"
"
"
"
"
"
A
L
H
H
L
"
80
A
"
"
"
"
B
"
"
"
A
H
L
L
H
B
81
"
8 2/ 4/ Same tests, terminal conditions, and limits as for subgroup 7, except TC=+125C and -55C.
See footnotes at end of device type 03.
|