| TABLE III. Group A inspection for device type 04.- Continued. 1/
NOTE: A = normal clock pulse, B = momentary GND, then 4.5 V, E = momentary GND, then open.
J = input pulse, tp ≥ 100 ns, VOL = 0 V, VOH = 4.5 V.
Terminal conditions (pins not designated may be H ≥ 2.0 V, or L ≤ 0.8 V, or open).
1/
2/
Tests shall be performed in sequence.
3/
Output voltages shall be either: (a) H = 2.4 V, minimum and L = 0.4 V, maximum when using a high speed checker double comparator; or
(b) H ≥ 1.5 V and L ≤ 1.5 V when using a high speed checker single comparator.
4/
Input voltages shown are: A = 2.4 V minimum and B = 0.4 V maximum.
5/
fMAX, minimum limit specified is the frequency of the input pulse. The output frequency shall be one-half of the input frequency.
*
These tests are performed at device manufacturer's option.
|