| MIL-M-38510/2G
NOTES:
1. Clear and preset inputs dominate regardless of the state of clock or D inputs.
2. All diodes are 1N3064, or equivalent.
3. Clear or preset input pulse characteristics: Vgen = 3 V, to ≤ 7 ns, tp (clear) = tp (preset) = 35 ns, and PRR =
1 MHz.
4. CL = 50 pF, minimum (including jig and probe capacitance).
5. RL = 390Ω 5%.
6. When testing clear to output switching, preset input shall have a negative pulse. When testing preset to
output switching, clear input shall have a negative pulse (see table III).
FIGURE 10. Clear and preset switching test circuit and waveforms for device types 05 and 07.
29
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |