| TABLE III. Group A inspection for device type 01. 1/ - Continued.
Subgroup
Symbol
MIL-
Case A, B, D
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Test limits
STD-883
Meas.
Case C
9
12
13
14
2
1
3
4
5
6
7
8
10
11
method
terminal
Test No.
K1
Clock
Preset
VCC
Clear
NC
J1
J2
J3
GND
Q
K2
K3
Min
Max
Unit
Q
7 2/ 4/
91
B
A
A
4.5 V
A
B
B
A
A
H
GND
L
A
A
All
H or L
TC = 25C
92
B
B
A
4.5 V
A
B
B
A
A
L
GND
H
A
A
output
As shown 3/
Same tests, terminal conditions and limits as for subgroup 7, except TC = 125 and -55C.
8 2/ 4/
9
FMAX 5/
(Fig. 5)
93
2.4 V
IN
5.0 V
5.0 V
5.0 V
2.4 V
2.4 V
2.4 V
GND
OUT
2.4 V
2.4 V
Q
10
MHz
TC = 25C
FMAX 5/
(Fig. 5)
94
"
IN
5.0 V
"
5.0 V
"
"
"
OUT
"
"
"
10
MHz
Q
"
tPLH1
3003
95
"
2.4 V
J
"
IN
"
"
"
OUT
"
"
"
Clear to Q
5
25
ns
"
tPLH1
(Fig. 4)
96
"
"
IN
"
J
"
"
"
"
OUT
"
"
Preset
"
25
"
to Q
"
tPHL1
"
97
"
"
J
"
IN
"
"
"
"
OUT
"
"
Clear to Q
"
40
"
"
tPHL1
"
98
"
"
IN
"
J
"
"
"
OUT
"
"
"
Preset
40
"
"
to Q
"
tPLH2
3003
99
"
IN
5.0 V
"
5.0 V
"
"
"
OUT
"
"
"
"
30
ns
Clock to Q
(Fig 5
"
tPLH2
"
100
"
"
"
"
"
"
"
"
"
OUT
"
"
Clock to Q
"
30
"
"
tPHL2
"
101
"
"
"
"
"
"
"
"
OUT
"
"
"
40
"
"
Clock to Q
"
tPHL2
"
102
"
"
"
"
"
"
"
"
"
OUT
"
"
Clock to Q
40
"
10
FMAX 5/
(Fig 5)
103
"
"
"
"
"
"
"
"
"
OUT
"
"
Q
10
MHz
TC = 125C
FMAX 5/
(Fig 5)
104
"
"
"
"
"
"
"
"
OUT
"
"
"
10
MHz
Q
"
tPLH1
3003
105
"
2.4 V
J
"
IN
"
"
"
OUT
"
"
"
5
39
ns
Clear to Q
(Fig. 4)
"
tPLH1
"
106
"
"
IN
"
J
"
"
"
"
OUT
"
"
Preset
"
39
"
to Q
"
tPHL1
"
107
"
"
J
"
IN
"
"
"
OUT
"
"
Clear to Q
"
50
"
"
tPHL1
"
108
"
"
IN
"
J
"
"
"
OUT
"
"
"
Preset
"
50
"
to Q
"
tPLH2
(Fig 5)
109
"
IN
5.0 V
"
5.0 V
"
"
"
OUT
"
"
"
"
39
ns
Clock to Q
"
tPLH2
"
110
"
"
"
"
"
"
"
"
"
OUT
"
"
Clock to Q
"
39
"
"
tPHL2
"
111
"
"
"
"
"
"
"
"
OUT
"
"
"
"
50
"
Clock to Q
"
tPHL2
"
112
"
"
"
"
"
"
"
"
OUT
"
"
Clock to Q
"
50
"
Same tests, terminal conditions and limits as for subgroup 10, except TC = -55C.
11
NOTES:
A = Normal clock pulse.
B = Momentary GND, then 4.5 V.
J = Input pulse tp = 100 ns, PRR = 1 MHz, VOL = 0 V, VOH = 4.5 V
*After clock pulse apply 12 mA to clock pin to insure Q is still in the low state (see figure 15).
1/ Terminal conditions (pins not designated may be H ≥ 2.0 V, or L ≤ 0.8 V, or open).
2/ Input voltages shown are: A= 2.0 volts minimum and B = 0.8 volts maximum.
3/ Output voltages shall be either: (a) H = 2.4 V, minimum and L = 0.4 V, maximum when using a high speed checker
double camparator; or (b) H ≥ 1.5 V and L < 1.5 V when using a high speed checker single comparator.
4/ Tests shall be performed in sequence.
5/ FMAX, minimum limit specified is the frequency of the input pulse. The output frequency shall be one-half of the input frequency.
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |