| TABLE III. Group A inspection for device type 04. 1/ - Continued.
Subgroup
Symbol
MIL-
Case E & F
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Test limits
STD-883
Meas.
Test No.
Clock 1
Preset 1
Clear 1
J1
VCC
Clock 2
Preset 2
Clear 2
J2
Q2
K2
GND
Q1
K1
Min
Max
Unit
Q2
Q1
method
terminal
9
tPHL2
3003
122
IN
5.0 V
2.4 V
5.0 V
GND
OUT
OUT
2.4 V
Clock 1
5
40
ns
TC = 25C
(Fig 8)
to Q 1
"
"
"
123
"
IN
5.0 V
5.0 V
2.4 V
OUT
2.4 V
"
Clock 2
"
"
"
to Q2
"
"
"
124
"
IN
5.0 V
5.0 V
2.4 V
OUT
2.4 V
"
Clock 2
"
"
"
to Q 2
10
FMAX 5/
(Fig 9)
125
IN
5.0 V
2.4 V
"
"
OUT
2.4 V
Q1
10
MHz
TC = 125C
"
126
IN
5.0 V
2.4 V
"
"
OUT
2.4 V
"
"
"
Q1
"
"
"
127
"
IN
5.0 V
5.0 V
2.4 V
OUT
2.4 V
"
Q2
"
"
"
"
"
128
"
IN
5.0 V
5.0 V
2.4 V
OUT
2.4 V
"
"
"
Q2
"
tPLH1
3003
129
2.4 V
5.0 V
IN
2.4 V
"
"
OUT
2.4 V
Clear 1
ns
5
39
(Fig 8)
to Q 1
"
"
"
130
2.4 V
IN
5.0 V
2.4 V
"
"
OUT
2.4 V
Preset 1
"
"
"
to Q1
"
"
"
131
"
2.4 V
5.0 V
IN
2.4 V
OUT
2.4 V
"
Clear 2
"
"
"
to Q 2
"
"
"
132
"
2.4 V
IN
5.0 V
2.4 V
OUT
2.4 V
"
Preset 2
"
"
"
to Q2
"
tPHL1
"
133
2.4 V
5.0 V
IN
2.4 V
"
"
OUT
2.4 V
Clear 1
"
50
"
to Q1
"
"
"
134
2.4 V
IN
5.0 V
2.4 V
"
"
OUT
2.4 V
Preset 1
"
"
"
to Q 1
"
"
"
135
"
2.4 V
5.0 V
IN
2.4 V
OUT
2.4 V
"
Clear 2
"
"
"
to Q2
"
"
"
136
"
2.4 V
IN
5.0 V
2.4 V
OUT
2.4 V
"
Preset 2
"
"
"
to Q 2
"
tPLH2
3003
137
IN
5.0 V
5.0 V
2.4 V
"
"
OUT
2.4 V
Clock 1
5
39
ns
(Fig 9)
to Q1
"
"
"
"
138
IN
5.0 V
5.0 V
2.4 V
"
"
OUT
2.4 V
Clock 1
"
"
to Q 1
"
"
"
139
"
IN
5.0 V
5.0 V
2.4 V
OUT
2.4 V
"
Clock 2
"
"
"
to Q2
"
"
"
140
"
IN
5.0 V
5.0 V
2.4 V
OUT
2.4 V
"
Clock 2
"
"
"
to Q 2
"
tPHL2
"
141
IN
5.0 V
5.0 V
2.4 V
"
"
OUT
2.4 V
Clock 1
"
50
"
to Q1
"
"
"
142
IN
5.0 V
5.0 V
2.4 V
"
"
OUT
2.4 V
Clock 1
"
"
"
to Q 1
"
"
"
143
"
IN
5.0 V
5.0 V
2.4 V
OUT
2.4 V
"
Clock 2
"
"
"
to Q2
"
"
"
144
"
IN
5.0 V
5.0 V
2.4 V
OUT
2.4 V
"
Clock 2
"
"
"
to Q 2
Same tests, terminal conditions and limits as for subgroup 10, except TC = -55C.
11
See notes at end of device type 04.
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |