| TABLE III. Group A inspection for device type 06. 1/ - Continued.
Subgroup
Symbol
MIL-STD-
Case A, B D
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Test limits
883
Meas.
Case C
10
12
13
14
2
1
3
4
5
6
7
8
9
11
method
terminal
Test No.
K1
Clock
Preset
VCC
GND
Q
Clear
NC
J1
J2
J*
K*
K2
Min
Max
Unit
Q
9
FMAX 5/
(Fig. 14)
93
2.4 V
IN
5.0 V
5.0 V
5.0 V
2.4 V
2.4 V
GND
GND
OUT
GND
2.4 V
Q
20
MHz
TC = 25C
FMAX 5/
(Fig. 14)
94
2.4 V
IN
5.0 V
"
5.0 V
2.4 V
2.4 V
GND
OUT
"
GND
2.4 V
20
MHz
Q
"
tPLH
3003
95
5.0 V
0.8 V
IN
"
IN
5.0 V
5.0 V
GND
OUT
"
GND
5.0 V
5
50
ns
Clear to Q
(Fig. 13)
"
tPLH
"
96
"
"
"
"
"
"
"
"
"
OUT
"
"
Preset to Q
"
"
"
"
tPHL
"
97
"
"
"
"
"
"
"
"
"
OUT
"
"
Clear to Q
"
"
"
"
tPHL
"
98
"
"
"
"
"
"
"
"
OUT
"
"
"
"
"
"
Preset to Q
"
(Fig. 15)
3003
99
2.4 V
IN
5.0 V
"
5.0 V
2.4 V
2.4 V
GND
"
OUT
GND
2.4 V
Clock to Q
5
50
ns
"
tPLH
(Fig. 14)
100
"
"
"
"
"
"
"
"
OUT
"
"
"
"
"
"
Clock to Q
"
tPHL
"
101
"
"
"
"
"
"
"
"
"
OUT
"
"
Clock to Q
"
"
"
"
tPHL
"
102
"
"
"
"
"
"
"
"
OUT
"
"
"
"
"
"
Clock to Q
10
FMAX 5/
(Fig. 14)
103
2.4 V
IN
5.0 V
"
5.0 V
2.4 V
2.4 V
GND
"
OUT
GND
2.4 V
Q
15
MHz
TC = 125C
FMAX 5/
(Fig. 14)
104
2.4 V
IN
5.0 V
"
5.0 V
2.4 V
2.4 V
GND
OUT
"
GND
2.4 V
15
MHz
Q
"
tPLH
3003
105
5.0 V
0.8 V
IN
"
IN
5.0 V
5.0 V
GND
OUT
"
GND
5.0 V
5
62
ns
Clear to Q
(Fig. 13)
"
tPLH
"
106
"
"
"
"
"
"
"
"
"
OUT
"
"
Preset to Q
"
"
"
"
tPHL
"
107
"
"
"
"
"
"
"
"
"
OUT
"
"
Clear to Q
"
"
"
"
tPHL
"
108
"
"
"
"
"
"
"
"
OUT
"
"
"
"
"
"
Preset to Q
"
tPLH
3003
109
2.4 V
IN
5.0 V
"
5.0 V
5.0 V
5.0 V
GND
"
OUT
GND
2.4 V
Clock to Q
5
62
ns
"
"
tPLH
(Fig. 14)
110
"
"
"
"
"
"
"
"
OUT
"
"
"
"
"
Clock to Q
"
tPHL
"
111
"
"
"
"
"
"
"
"
"
OUT
"
"
Clock to Q
"
"
"
"
tPHL
"
112
"
"
"
"
"
"
"
"
OUT
"
"
"
"
"
"
Clock to Q
Same tests, terminal conditions and limits as for subgroup 10, except TC = -55C.
11
NOTES:
A = Normal clock pulse.
B = Momentary GND, then 4.5 V.
1/ Terminal conditions (pins not designated may be H ≥ 2.0 V, or L ≤ 0.8 V, or open).
2/ Input voltages shown are: A = 2.0 V minimum and B = 0.8 V maximum.
3/ Output voltages shall be either: (a) H = 2.4 V, minimum and L = 0.4 V, maximum when using a high speed checker double comparator; or (b)
H ≥ 1.5 V and L < 1.5 V when using a high speed checker single comparator.
4/ Tests shall be performed in sequence.
5 FMAX, minimum limit specified is the frequency of the input pulse. The output frequency shall be one-half of the input frequency.
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |