| TABLE III. Group A inspection for device type 01 Continued.
Terminal conditions (pins not designated may be high ≥ 2.0 V, low ≤ 0.7 V, or open).
Cases
1
2
3
4
5
6
7
8
9
10
11
12
13
14
A,B,C,D
MIL-STD-
Subgroup
Symbol
883
Case 2
2
3
4
6
8
9
10
12
13
14
16
18
19
20
Measured
Limits
Unit
terminal
method
1/
Test no.
1A
2A
2B
2C
2D
2Y
GND
1Y
1D
1E
1F
1B
1C
VCC
Min
Max
10
tPLH
3003
84
IN
GND
OUT
GND
GND
GND
2.7 V
2.7 V
5.0 V
1A to 1Y
3
30
ns
Tc = 125C
Fig. 3
85
2.7 V
"
"
"
"
"
IN
2.7 V
"
1B to 1Y
"
"
"
"
86
2.7 V
"
"
"
"
"
2.7 V
IN
"
1C to 1Y
"
"
"
"
87
GND
"
"
IN
2.7 V
2.7 V
GND
GND
"
1D to 1Y
"
"
"
"
88
"
"
"
2.7 V
IN
2.7 V
"
"
"
1E to 1Y
"
"
"
"
89
"
"
"
2.7 V
2.7 V
IN
"
"
"
1F to 1Y
"
"
"
"
90
IN
2.7 V
GND
GND
OUT
"
"
2A to 2Y
"
"
"
"
91
2.7 V
IN
GND
GND
"
"
"
2B to 2Y
"
"
"
"
92
GND
GND
IN
2.7 V
"
"
"
2C to 2Y
"
"
"
"
93
GND
GND
2.7 V
IN
"
"
"
2D to 2Y
"
"
"
Same tests, terminal conditions and limits as for subgroup 10, except TC = -55 C.
11
See footnotes at end of table.
|