| TABLE III. Group A inspection for device type 02 Continued.
Terminal conditions (pins not designated may be high ≥ 2.0 V, low ≤ 0.7 V, or open).
Cases
1
2
3
4
5
6
7
8
9
10
11
12
13
14
A,B,C,D
MIL-STD-
Subgroup
Symbol
883
Case 2
2
3
4
6
8
9
10
12
13
14
16
18
19
20
Measured
Limits
Unit
terminal
method
1/
Test no.
A
B
C
D
E
Y
GND
NC
F
G
H
I
J
VCC
Min
Max
10
tPLH
3003
81
IN
2.7 V
GND
GND
GND
OUT
GND
GND
GND
GND
GND
GND
5.0 V
A to Y
3
30
ns
Tc = 125C
Fig. 3
82
2.7 V
IN
GND
GND
GND
"
"
"
"
"
"
"
"
B to Y
"
"
"
"
83
GND
GND
IN
2.7 V
2.7 V
"
"
"
"
"
"
"
"
C to Y
"
"
"
"
84
"
"
2.7 V
IN
2.7 V
"
"
"
"
"
"
"
"
D to Y
"
"
"
"
85
"
"
2.7 V
2.7 V
IN
"
"
"
"
"
"
"
"
E to Y
"
"
"
"
86
"
"
GND
GND
GND
"
"
IN
2.7 V
2.7 V
"
"
"
F to Y
"
"
"
"
87
"
"
"
"
"
"
"
2.7 V
IN
2.7 V
"
"
"
G to Y
"
"
"
"
88
"
"
"
"
"
"
"
2.7 V
2.7 V
IN
"
"
"
H to Y
"
"
"
"
89
"
"
"
"
"
"
"
GND
GND
GND
IN
2.7 V
"
I to Y
"
"
"
"
90
"
"
"
"
"
"
"
"
"
"
2.7 V
IN
"
J to Y
"
"
"
Same tests, terminal conditions and limits as for subgroup 10, except TC = -55 C.
11
1/ Case 2 pins not referenced are NC.
2/ IIL limits are as follows:
Min/Max limits in mA for circuit
Parameters
A
B
C
D
E
F
IIL
-120/-360
-30/-300
-150/-380
-120/-360
-105/-345
-150/-380
3/ tPLH max limit for CKT C is 25 ns.
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |