MIL-M-38510/306E
TABLE I. Electrical performance characteristics - Continued.
Limits
Test
Symbol
Conditions 1/
Device
Unit
-55C < TC < +125C
types
Min
Max
unless otherwise specified
VCC = 5.0, CL = 50 pF 10%
Propagation delay
02
5
53
ns
tPLH2
RL = 2 kfor types 01 thru 05, 08 and
time, low-to-high
level form preset
09. See figures 9 and 10 for RL types
04
60
or preset enable
06 and 07
Propagation delay
tPLH1
01,02
5
47
ns
time, high-to-low
level from clock
03,05,07
56
04
68
06
52
08
58
09
46
Propagation delay
tPLH2
01,02
05
53
ns
time, high-to-low
level from clear
07
56
05
62
04
90
Propagation delay
08,09
5
52
ns
tPLH5
time, low to high
level from S/L
Propagation delay
08,09
5
52
ns
tPHL5
time, high to low
level from S/L or
clear
Propagation delay
08
5
46
ns
tPHL3
time, high to low
level from data
Propagation delay
08
5
39
ns
tPLH3
time, low to high
level from data