| MIL-M-38510/308B
TABLE I. Electrical performance characteristics - Continued.
Conditions 1/
Limits
Unit
Test
Symbol
-55C ≤ TC ≤ +125C
Min
Max
Propagation delay times, low to high level output: 5/, 6/
VCC = 5.0 V, See figure 4
2
55
ns
tPLH1
A i or B i to any F , sum mode
sum mode test table
VCC = 5.0 V, See figure 4
2
55
ns
tPLH2
A i or B i to any F , diff mode
diff mode test table
VCC = 5.0 V, See figure 4
2
52
ns
tPLH3
A i or B i to any P , sum mode
sum mode test table
VCC = 5.0 V, See figure 4
2
52
ns
tPLH4
A i or B i to P , diff mode
diff mode test table
VCC = 5.0 V, See figure 4
2
51
ns
tPLH5
A i or B i to G , sum mode
sum mode test table
VCC = 5.0 V, See figure 4
2
55
ns
tPLH6
A i or B i to G , diff mode
diff mode test table
VCC = 5.0 V, See figure 4
2
46
ns
tPLH7
Cn to any F , sum mode
sum mode test table
VCC = 5.0 V, See figure 4
2
76
ns
tPLH8
A i to B i to A = B, diff mode
diff mode test table
VCC = 5.0 V, See figure 4
2
48
ns
tPLH9
Cn to Cn+4, sum mode
sum mode test table
VCC = 5.0 V, See figure 4
2
48
ns
tPLH10
Cn to Cn+4, diff mode
diff mode test table
tPLH11
VCC = 5.0 V, See figure 4
2
64
ns
A i or B i to Cn+4, sum mode
sum mode test table
tPLH12
VCC = 5.0 V, See figure 4
2
69
ns
A i or B i to Cn+4, diff mode
diff mode test table
tPLH13
VCC = 5.0 V, See figure 4
2
57
ns
A i or B i to any F , logic mode
logic mode test table
1/ Condition of inputs specified in table III.
2/ All unspecified inputs at 5.5 V.
3/ All unspecified inputs at 0 V.
4/ Not more than one output should be shorted at a time.
5/ In A i and B i i = 0, 1, 2, 3.
6/ CL = 50 pF 10%, RL = 2 kΩ 5%.