| TABLE III. Group A inspection for device type 01 - Continued.
Terminal conditions (pins not designated may be high ≥ 2.0 V; low ≤ 0.7 V; or open).
Cases
1
2
3
4
5
6
7
8
9
10
11
12
J, K, Z
MIL-STD-
Subgroup
Symbol
883
Case
2
3
4
5
6
7
9
10
11
12
13
14
Measured
Limits
Unit
3 1/
method
terminal
S3
S2
S1
S0
Cn
M
GND
Min
Max
Test no.
B0
A0
F0
F1
F2
2
32
ns
9
tPLH6
3003
209
4.5 V
IN
GND
4.5 V
4.5 V
GND
GND
GND
GND
A 0 to G
Tc = 25C
Fig 4
210
GND
GND
"
"
"
"
"
"
"
"
"
"
A 1 to G
"
"
"
"
211
GND
"
"
"
"
"
"
"
"
A 2 to G
"
"
"
"
212
GND
"
"
"
"
"
"
"
"
A 3 to G
"
"
"
"
213
IN
"
"
"
"
"
"
"
"
B 0 to G
"
"
"
"
214
GND
"
"
"
"
"
"
"
"
B 1 to G
"
"
"
"
215
GND
"
"
"
"
"
"
"
"
B 2 to G
"
"
"
"
216
GND
"
"
"
"
"
"
"
"
B 3 to G
tPHL7
"
217
"
4.5 V
4.5 V
GND
GND
4.5 V
IN
"
OUT
"
"
25
"
Cn to F 0
"
26
"
tPLH7
"
218
"
4.5 V
4.5 V
GND
GND
4.5 V
IN
"
OUT
"
Cn to F 0
tPHL8
"
219
"
IN
GND
4.5 V
4.5 V
GND
GND
"
"
"
75
"
A 0 to A = B
"
220
"
4.5 V
"
"
"
"
"
"
"
"
"
"
A 1 to A = B
"
221
"
"
"
"
"
"
"
"
"
"
"
"
A 2 to A = B
"
222
"
"
"
"
"
"
"
"
"
"
"
"
A 3 to A = B
"
223
IN
"
"
"
"
"
"
"
"
"
"
"
B 0 to A = B
"
224
GND
"
"
"
"
"
"
"
"
"
"
"
B 1 to A = B
"
225
"
"
"
"
"
"
"
"
"
"
"
"
B 2 to A = B
"
226
"
"
"
"
"
"
"
"
"
"
"
"
B 3 to A = B
tPHL8
"
227
"
IN
"
"
"
"
"
"
"
"
80
"
A 0 to A = B
"
228
"
4.5 V
"
"
"
"
"
"
"
"
"
"
A 1 to A = B
"
229
"
"
"
"
"
"
"
"
"
"
"
"
A 2 to A = B
"
230
"
"
"
"
"
"
"
"
"
"
"
"
A 3 to A = B
"
231
IN
"
"
"
"
"
"
"
"
"
"
"
B 0 to A = B
"
232
GND
"
"
"
"
"
"
"
"
"
"
"
B 1 to A = B
"
233
"
"
"
"
"
"
"
"
"
"
"
"
B 2 to A = B
"
234
"
"
"
"
"
"
"
"
"
"
"
"
B 3 to A = B
tPHL9
"
235
"
"
4.5 V
GND
GND
4.5 V
IN
"
"
Cn to Cn+4
"
25
"
tPLH9
"
236
"
"
4.5 V
GND
GND
4.5 V
"
"
"
Cn to Cn+4
"
26
"
tPHL10
"
237
4.5 V
"
GND
4.5 V
4.5 V
GND
"
"
"
Cn to Cn+4
"
25
"
tPLH10
"
238
4.5 V
"
GND
4.5 V
4.5 V
GND
"
"
"
Cn to Cn+4
"
26
"
See footnotes at end of table. Pins 13 thru 24 on next page.
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |