| TABLE III. Group A inspection for device type 01 - Continued.
Terminal conditions (pins not designated may be high ≥ 2.0 V; low ≤ 0.7 V; or open).
Cases
1
2
3
4
5
6
7
8
9
10
11
12
J, K, Z
MIL-STD-
Subgroup
Symbol
883
Case
2
3
4
5
6
7
9
10
11
12
13
14
Measured
Limits
Unit
3 1/
method
terminal
S3
S2
S1
S0
Cn
M
GND
Min
Max
Test no.
B0
A0
F0
F1
F2
9
tPHL11
3003
239
GND
IN
4.5 V
GND
GND
4.5 V
GND
GND
GND
2
40
ns
A 0 to Cn+4
Tc = 25C
Fig 4
240
4.5 V
GND
"
"
"
"
"
"
"
"
"
"
A 1 to Cn+4
"
241
4.5 V
"
"
"
"
"
"
"
"
"
"
"
A 2 to Cn+4
"
242
4.5 V
"
"
"
"
"
"
"
"
"
"
"
A 3 to Cn+4
"
243
IN
"
"
"
"
"
"
"
"
"
"
"
B 0 to Cn+4
"
244
4.5 V
"
"
"
"
"
"
"
"
"
"
"
B 1 to Cn+4
"
245
4.5 V
"
"
"
"
"
"
"
"
"
"
"
B 2 to Cn+4
"
246
4.5 V
"
"
"
"
"
"
"
"
"
"
"
B 3 to Cn+4
tPLH11
"
247
GND
IN
"
"
"
"
"
"
"
"
38
"
A 0 to Cn+4
"
248
4.5 V
GND
"
"
"
"
"
"
"
"
"
"
A 1 to Cn+4
"
249
4.5 V
"
"
"
"
"
"
"
"
"
"
"
A 2 to Cn+4
"
250
4.5 V
"
"
"
"
"
"
"
"
"
"
"
A 3 to Cn+4
"
251
IN
"
"
"
"
"
"
"
"
"
"
"
B 0 to Cn+4
"
252
4.5 V
"
"
"
"
"
"
"
"
"
"
"
B 1 to Cn+4
"
253
4.5 V
"
"
"
"
"
"
"
"
"
"
"
B 2 to Cn+4
"
254
4.5 V
"
"
"
"
"
"
"
"
"
"
"
B 3 to Cn+4
tPHL12
"
255
4.5 V
IN
GND
4.5 V
4.5 V
GND
"
"
"
"
46
"
A 0 to Cn+4
"
256
GND
GND
"
"
"
"
"
"
"
"
"
"
A 1 to Cn+4
"
257
GND
"
"
"
"
"
"
"
"
"
"
"
A 2 to Cn+4
"
258
GND
"
"
"
"
"
"
"
"
"
"
"
A 3 to Cn+4
"
259
IN
"
"
"
"
"
"
"
"
"
"
"
B 0 to Cn+4
"
260
GND
"
"
"
"
"
"
"
"
"
"
"
B 1 to Cn+4
"
261
GND
"
"
"
"
"
"
"
"
"
"
"
B 2 to Cn+4
"
262
GND
"
"
"
"
"
"
"
"
"
"
"
B 3 to Cn+4
tPLH12
"
263
4.5 V
IN
"
"
"
"
"
"
"
"
40
"
A 0 to Cn+4
"
264
GND
GND
"
"
"
"
"
"
"
"
"
"
A 1 to Cn+4
"
265
GND
"
"
"
"
"
"
"
"
"
"
"
A 2 to Cn+4
"
266
GND
"
"
"
"
"
"
"
"
"
"
"
A 3 to Cn+4
"
267
IN
"
"
"
"
"
"
"
"
"
"
"
B 0 to Cn+4
"
268
GND
"
"
"
"
"
"
"
"
"
"
"
B 1 to Cn+4
"
269
GND
"
"
"
"
"
"
"
"
"
"
"
B 2 to Cn+4
"
270
GND
"
"
"
"
"
"
"
"
"
"
"
B 3 to Cn+4
See footnotes at end of table. Pins 13 thru 24 on next page.
|