| ![]() MIL-M-38510/316E
TABLE I. Electrical performance characteristics.
Test
Symbol
Conditions
Device
Limits
Unit
-55C ≤ TC ≤ +125C
type
Min
Max
High level output voltage
VOH
VCC = 4.5 V, VIH = 2.0 V
All
2.5
V
VIL = 0.7 V, IOH = -400 A
Low level output voltage
VOL
VCC = 4.5 V, VIH = 2.0 V
All
0.4
V
VIL = 0.7 V, IOL = 4 mA
Input clamp voltage
VI C
VCC = 4.5 V, IIN = -18 mA,
All
-1.5
V
TC = +25C
Low level input current:
IIL1
VCC = 5.5 V, VIN = 0.4 V
01
-.03
-0.42
mA
At data
04
-.0005
-0.4
02
0
-0.4
At S , R
At all inputs
03, 05
-.005
-0.72
Low level input current
IIL2
VCC = 5.5 V, VIN = 0.4 V
01
-.06
-1.6
mA
enable
04
0
-1.6
A
High level input current:
IIH1
VCC = 5.5 V, VIN = 2.7 V
01, 04
20
At data
02
20
At S , R
At all inputs
03, 05
20
A
High level input current
IIH2
VCC = 5.5 V, VIN = 2.7 V
01, 04
80
enable
A
High level input current:
IIH3
VCC = 5.5 V, VIN = 5.5 V
01, 04
100
At data
02
100
At S , R
At all inputs
03, 05
100
A
High level input current
IIH4
VCC = 5.5 V, VIN = 5.5 V
01, 04
400
enable
Short circuit output current IOS
VCC = 5.5 V 1/
All
-15
-100
mA
Supply current
ICC
VCC = 5.5 V
01, 04
12
mA
02
7
03, 05
36
CL = 50 pF 10%, RL = 2 kΩ 5%
01, 04
3
42
ns
Low to high level, from
tPLH1
D input to Q output
VCC = 5.0 V
High to low level, from
tPHL1
01, 04
3
29
ns
D input to Q output
Low to high level, from
01, 04
3
32
ns
tPLH2
D input to Q output
High to low level, from
01, 04
3
26
ns
tPHL2
D input to Q output
Low to high level, from
tPLH3
01, 04
3
42
ns
enable input to Q output
High to low level, from
tPHL3
01, 04
3
39
ns
enable input to Q output
1/ Not more than one output should be shorted at one time.
5
|