| ![]() TABLE III. Group A inspection for device type 05.
Terminal conditions (pins not designated may be high ≥ 2.0 V; low ≤ 0.7 V; or open).
Cases
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
MIL-STD-
E, F
Subgroup
Symbol
883
Cases
2
3
4
5
7
8
9
10
12
13
14
15
17
18
19
20
Measured
Limits
Unit
method
2, X
terminal
Test no.
A
B
C
Q0
Q1
Q2
Q3
GND
Q4
Q5
Q6
Q7
DATA
Min
Max
VCC
ENBL
CLR
IN
9
tPHL4
3003
179
GND
IN
GND
OUT
GND
GND
IN
4.5 V
5.0 V
3
29
ns
ENBL to Q2
TC = 25C
tPLH4
Fig 5
180
"
"
"
"
"
4.5 V
"
"
"
"
"
"
ENBL to Q2
tPHL4
181
"
"
"
"
"
GND
"
"
"
"
"
"
ENBL to Q2
tPHL4
182
"
GND
IN
"
OUT
GND
"
"
"
"
"
"
ENBL to Q4
tPLH4
183
"
"
"
"
"
4.5 V
"
"
"
"
"
"
ENBL to Q4
tPHL4
184
"
"
"
"
"
GND
"
"
"
"
"
"
ENBL to Q4
tPHL4
185
IN
"
GND
OUT
"
GND
"
"
"
"
"
"
ENBL to Q0
tPLH4
186
"
"
"
"
"
4.5 V
"
"
"
"
"
"
ENBL to Q0
tPHL4
187
"
"
"
"
"
GND
"
"
"
"
"
"
ENBL to Q0
tPHL4
188
4.5 V
IN
4.5 V
"
OUT
GND
"
"
"
"
"
"
ENBL to Q5
tPLH4
189
"
"
"
"
"
4.5 V
"
"
"
"
"
"
ENBL to Q5
tPHL4
190
"
"
"
"
"
GND
"
"
"
"
"
"
ENBL to Q5
tPHL4
191
"
4.5 V
IN
OUT
"
GND
"
"
"
"
"
"
ENBL to Q3
tPLH4
192
"
"
"
"
"
4.5 V
"
"
"
"
"
"
ENBL to Q3
tPHL4
193
"
"
"
"
"
GND
"
"
"
"
"
"
ENBL to Q3
10
tPHL1
"
30
"
TC =125C
Same tests and terminal conditions as for subgroup 9, except TC = +125C and test limits as shown
tPLH2
"
46
"
tPHL2
"
33
"
tPLH3
"
42
"
tPHL3
"
42
"
tPLH4
"
38
"
tPHL4
"
38
"
Same tests, terminal conditions and limits as for subgroup 10, except TC = -55C.
11
1/ Apply a 3V/0V/3V momentary pulse 500 ns minimum prior to measurements.
2/ A = 2.4 V, B = 0.4 V.
3/ H ≥ 1.5 V, L ≤ 1.5 V.
4/ IIL limits are as follows:
Min/max limits (mA)
Symbol
Circuit B, C
Circuit A
Device 03
Device 05
IIL1
-.12/-.36
-.16/-.40
Test 21
-.005/-.72
Test 21
-.005/-0.20
5/ See note 6 of figure 5.
4.5V ─┐ ┌─ 4.5 v
6/ Apply
momentary pulse prior to each test.
0 V └──┘
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |