| MIL-M-38510/328C
TABLE I. Electrical performance characteristics.
Test
Symbol
Conditions
Device
Limits
Unit
-55C ≤ TC ≤ +125C
type
Min
Max
High level output voltage
VOH1
VCC = 4.5 V, VIH = 2.0 V, VIL = 0.7 V
01, 02, 03
2.4
V
IOH = -3 mA
VIL = 0.5 V
04, 05
2.4
"
VOH2
VCC = 4.5 V, VIH = 2.0 V, VIL = 0.5 V
01, 02, 03
2.0
"
IOH = -12 mA
VIL = 0.5 V
04, 05
2.0
"
High level output voltage
VOL
VCC = 4.5 V, VIH = 2.0 V, VIL = 0.7 V
01, 02, 03
0.4
"
IOL = 12 mA
VIL = 0.5 V
04, 05
0.4
"
Input clamp voltage
VI C
VCC = 4.5 V, IIN = -18 mA,
All
-1.5
"
TC = +25C
A
High level input current
IIH1
VCC = 5.5 V, VIN = 2.7 V
All
20
High level input current
IIH2
VCC = 5.5 V, VIN = 5.5 V
All
0.1
mA
A
Inhibited state output
IOZH
VCC = 5.5 V, VOUT = 2.7 V
01, 02
40
leakage current
03
20
04, 05
20
A
IOZL
VCC = 5.5 V, VOUT = 0.4 V
01, 02, 03
-200
04, 05
-400
A
Low level input current
IIL
VCC = 5.5 V, VIN = 0.4 V
01, 02, 03
0
-240
04, 05
0
-200
Short circuit output current
IOS
VCC = 5.5 V
1/
All
-40
-225
mA
Supply current
ICCH
VCC = 5.5 V
01, 02
38
mA
03
70
04, 05
145
ICCL
VCC = 5.5 V
01, 02
50
mA
03
90
04, 05
165
ICCZ
VCC = 5.5 V
01, 02
50
mA
03
95
04, 05
165
Propagation delay time,
tPLH1
VCC = 5.0 V,
04, 05
2
39
ns
RL = 110Ω,
low to high clock to bus
Propagation delay time,
tPHL1
CL = 50 pF
04
2
52
ns
high to low clock to bus
05
2
59
Propagation delay time,
tPLH2
01, 02
2
25
ns
low to high bus to bus
03
2
22
04, 05
2
30
ns
See footnote at end of table.
5
|