MIL-M-38510/328C
TABLE II. Electrical test requirements.
Subgroups (see table III)
MIL-PRF-38535
Class S
Class B
test requirements
devices
devices
Interim electrical parameters
1
1
Final electrical test parameters
1*, 2, 3, 7, 8,
1*, 2, 3, 7, 8, 9
9, 10, 11
Group A test requirements
1, 2, 3, 7, 8
1, 2, 3, 7, 8, 9
9, 10, 11
Group B electrical test parameters
1, 2, 3, 7, 9,
N/A
when using the method 5005 QCI option
10, 11
Group C end-point electrical
1, 2, 3, 7,
1, 2, 3
parameters
9, 10, 11
Additional electrical subgroups for
N/A
10, 11
group C periodic inspections
Group D end-point electrical parameters
1, 2, 3
1, 2, 3
*PDA applies to subgroup 1.
4.4.4 Group D inspection. Group D inspection shall be in accordance with table V of MIL-PRF-38535. End-point
electrical parameters shall be as specified in table II herein.
4.5 Methods of inspection. Methods of inspection shall be specified and as follows:
4.5.1 Voltage and current. All voltages given are referenced to the microcircuit ground terminal. Currents given are
conventional and positive when flowing into the referenced terminal.
4.6 Inclusion with other detail specifications. For qualification and quality conformance inspection purposes, devices
covered by this specification may be treated as though they were included on the same detail specification as devices
covered by MIL-M-38510/324. In addition, if a manufacturer is already qualified for type 32402, and if the respective
devices on this specification (MIL-M-38510/328) are designed and manufactured identically (same die, same process,
same screening) in all respects except electrical testing, then device type 32802 may be qualified by conducting only
group A electrical tests with approval of the qualifying activity including subgroups A-10 and A-11, and submitting data in
accordance with MIL-M-38510, appendix D (i.e., groups B, C, and D tests are not required).