| TABLE III. Group A inspection for device type 01.
Terminal conditions (pins not designated may be high ≥ 2.0 V, or low ≤ 0.7 V, or open).
Cases
1
2
3
4
5
6
7
8
9
10
11
12
13
14
MIL-STD-
A, C, D
2
3
4
6
8
9
10
12
13
14
16
18
19
20
Measured
Limits
Unit
Subgroup
Symbol
883
Case
2 1/
terminal
method
NC
1A
2A
3A
4A
GND
4B
3B
2B
1B
NC
GBA
VCC
Test no.
Min
Max
GAB
1
VOH1
3006
1
0.7 V
0.7 V
GND
-3 mA
0.7 V
4.5 V
1B
2.4
V
Tc = 25C
"
2
"
0.7 V
"
-3 mA
"
"
2B
"
"
"
3
"
0.7 V
"
-3 mA
"
"
3B
"
"
"
4
"
0.7 V
"
-3 mA
"
"
4B
"
"
"
5
2.0 V
-3 mA
"
0.7 V
2.0 V
"
1A
"
"
"
6
"
-3 mA
"
0.7 V
"
"
2A
"
"
"
7
"
-3 mA
"
0.7 V
"
"
3A
"
"
"
8
"
-3 mA
"
0.7 V
"
"
4A
"
"
VOH2
"
9
0.5 V
0.5 V
"
-12 mA
0.5 V
"
1B
2.0
"
"
10
"
0.5 V
"
-12 mA
"
"
2B
"
"
"
11
"
0.5 V
"
-12 mA
"
"
3B
"
"
"
12
"
0.5 V
"
-12 mA
"
"
4B
"
"
"
13
2.0 V
-12 mA
"
0.5 V
2.0 V
"
1A
"
"
"
14
"
-12 mA
"
0.5 V
"
"
2A
"
"
"
15
"
-12 mA
"
0.5 V
"
"
3A
"
"
"
16
"
-12 mA
"
0.5 V
"
"
4A
"
"
VOL
3007
17
0.7 V
2.0 V
"
12 mA
0.7 V
"
1B
0.4
"
"
18
"
2.0 V
"
12 mA
"
"
2B
"
"
"
19
"
2.0 V
"
12 mA
"
"
3B
"
"
"
20
"
2.0 V
"
12 mA
"
"
4B
"
"
"
21
2.0 V
12 mA
"
2.0 V
2.0 V
"
1A
"
"
"
22
"
12 mA
"
2.0 V
"
"
2A
"
"
"
23
"
12 mA
"
2.0 V
"
"
3A
"
"
"
24
"
12 mA
"
2.0 V
"
"
4A
"
"
IOZH
25
2.7 V
"
0.7 V
5.5 V
1A
2/
2/
26
2.7 V
"
"
"
2A
"
"
27
2.7 V
"
"
"
3A
"
"
28
2.7 V
"
"
"
4A
"
"
29
2.0 V
"
2.7 V
"
1B
"
"
30
"
"
2.7 V
"
2B
"
"
31
"
"
2.7 V
"
3B
"
"
32
"
"
2.7 V
"
4B
"
"
A
IOZL
33
0.4 V
"
0.7 V
"
1A
-200
34
0.4 V
"
"
"
2A
"
"
35
0.4 V
"
"
"
3A
"
"
36
0.4 V
"
"
"
4A
"
"
37
2.0 V
"
0.4 V
"
1B
"
"
38
"
"
0.4 V
"
2B
"
"
39
"
"
0.4 V
"
3B
"
"
40
"
"
0.4 V
"
4B
"
"
3/
IIL
3009
41
0.4 V
"
"
3/
"
GAB
"
42
0.4 V
"
GND
"
1A
"
"
"
"
43
0.4 V
"
"
"
2A
"
"
"
"
44
0.4 V
"
"
"
3A
"
"
"
"
45
0.4 V
"
"
"
4A
"
"
"
"
46
5.5 V
"
0.4 V
"
4B
"
"
"
"
47
"
"
0.4 V
"
3B
"
"
"
"
48
"
"
0.4 V
"
2B
"
"
"
"
49
"
"
0.4 V
"
1B
"
"
"
"
50
"
0.4 V
"
GBA
"
"
"
See footnotes at end of device type 01.
|